4.2.9. Any Remotes that are not within communications range will not be armed.
4.2.10. When ready to fire, press the two FIRE switches together at the same time and hold for
½ Second as shown. Shot initiation in surface mines is normally detected.
Figure 4-8 Motion Detect Screen
After firing, the following Motion Detect Screen will be shown as in
4.2.11. Figure 4-8. About 10 seconds later, the screen will be updated for any units that have
detected a motion that was likely caused by the blast.
Figure 4-9 Verify the green READY Lights are on steady
4.2.12. At the same time the Motion Detect Screen is displayed, the REMOTE UNIT display will
but updated as shown in Figure 4-9. Any READY lights which continue to blink indicate that the
Controller did not get a response that Remote Unit. Do not approach those Remote Units which
remain blinking until you get a solid green READY light to indicate they are confirmed to be
disarmed and safe for approach.