9. BASIC TROUBLESHOOTING IN THE FIELD
9.1. REMOTE UNIT
9.1.1. Will not Initiate shock tube
a) Igniter tip may be worn or damaged. Try a new tip.
b) There may be water on tip. Blow out tip and test fire the tip without any tube installed.
c) Shock tube may be damaged. Cut a fresh section.
d) Unit needs recharging.
9.1.2. Charger does not work
a) Ensure the battery charger and RFD Units are indoors and the air temperature is between 32
and 86 F (0 to 30 C)
9.2. CONTROLLER UNIT
9.2.1. Charger does not work
a) Ensure the battery charger and RFD Units are indoors and the air temperature is between 32
and 86 F (0 to 30 C)
9.2.2. The ARMED and READY lights will not come on or blink continuously
a) The Remote Unit is out of 2-way range of Controller Unit.
b) The Remote Unit is within 2-way range of the Controller Unit.
Check for damage to Controller Unit antenna or antenna jack
Check for damage to Remote Unit antenna or antenna jack.
Move at least 10 meters in any direction and try again.
Reposition any units if:
The antenna is not positioned vertically.
The Unit is isolated by large dirt walls, rocks, or metal objects.
The antenna is next to another radio antenna.