2V Heavy-Duty Fuel Transfer Pump Gasoline Compatible Owner’s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury.
Thank you very much for choosing a Roughneck™ product! For future reference, please complete the owner’s record below: Serial Number/Lot Date Code: ________________________________ Purchase Date: ____________________________________________ Save the receipt, warranty, and this manual. It is important that you read the entire manual to become familiar with this product before you begin using it. This fuel transfer pump is designed for certain applications only.
Table of Contents Intended Use .......................................................................................................................................... 4 Packaging Contents .............................................................................................................................. 4 Technical Specifications ...................................................................................................................... 4 Electrical Specifications ....................
Intended Use This 12V Heavy-Duty Fuel Transfer Pump is a positive displacement, rotary vane pump. Depending on installation and viscosity, this pump can deliver up to 20GPM or 76 LPM. The rugged design makes for a long life of dependability. Packaging Contents No. Description Qty. No. Description Qty.
Do not modify this product in any way. Unauthorized modification may impair the function and/or safety and could affect the life of the product. There are specific applications for which the product was designed. Use the right tool for the job. DO NOT attempt to force small equipment to do the work of larger industrial equipment. There are certain applications for which this equipment was designed. This product will be safer and do a better job at the capacity for which it was intended.
injury. Secure the work with clamps or a vise instead of your hand when practical. This safety precaution allows for proper tool operation using both hands. ⚠CAUTION PUMP USE AND CARE Do not force the pump. Products are safer and do a better job when used in the manner for which they are designed. Plan your work, and use the correct product for the job. Check for damaged parts before each use. Carefully check that the product will operate properly and perform its intended function.
not operate the system in the presence of any source of ignition including running or hot engines, lighted cigarettes, or gas or electric heaters. Observe precautions against electrical shock when operating the system. Serious or fatal shock can result from operating electrical equipment in damp or wet locations. Inspect external pump wiring regularly to make sure it is correctly attached to the battery. To avoid electrical shock, use extra care when connecting the pump to power.
Main Parts of Product No. Description Qty. No. Description Qty.
13 Pump chamber 1 32 Switch bracket 1 14 Bypass valve 1 33 Nozzle holder 1 15 O-ring 1 34 Nozzle 1 16 Filter screen 1 35 Screw 2 17 2” Bung adapter 1 18 Screw 2 19 Suction tube 1 Assembly Instructions 1. Tightly screw suction pipe into inlet coupling of pumping unit. Extend suction pipe into truck tank or barrel to within 3" of tank bottom. 2. Screw inlet coupling of pump into 2" tank or barrel opening.
Before Each Use ⚠WARNING To prevent serious injury or property damage, read and understand owner’s manual before operating. Know and follow applicable national, state, and local safety codes pertaining to installing and operating electrical equipment for use with flammable liquids. Know and follow all safety precautions when handling petroleum fuels. Ensure that all equipment operators have access to adequate instructions concerning safe operating and maintenance procedures.
electrical shock, use extra care when connecting the pump to power. Avoid prolonged skin contact with petroleum fuels. Use protective goggles, gloves and aprons in case of splashing or spills. Change saturated clothing and wash skin promptly with soap and water. Wear the proper protective gear including ANSI Z87.1 compliant safety goggles while operating. This product should not be used for fluid transfer into an aircraft.
If using solvent to clean pump components or tank, observe the solvent manufacturer’s recommendations for safe use and disposal. Burn hazard. To reduce the risk of burns, do not touch hot surfaces. Store the product when it is not in use. Store it in a dry, secure place out of the reach of children. Inspect the tool for good working condition prior to storage and before re-use.
(working with the by-pass open) diameter Dismantle the valve, clean and/or By-pass valve blocked replace it Air entering the pump or the Check the seals of the connections suction tubing A narrowing in the suction Use tubing suitable for working tubing under suction pressure Check the voltage at the pump.
Parts Diagram Parts List No. Description Qty. No. Description Qty.
No. Description Qty. No. Description Qty. 11 Bypass spring 1 30 Screw 6 12 Electric motor 1 31 Grounded screw 1 13 Pump chamber 1 32 Switch bracket 1 14 Bypass valve 1 33 Nozzle holder 1 15 O-ring 1 34 Nozzle 1 16 Filter screen 1 35 Screw 2 17 2" Bung adapter 1 18 Screw 2 19 Suction tube 1 Replacement Parts For replacement parts and technical questions, please call Customer Service at 1-800-222-5381.
Limited Warranty Northern Tool and Equipment Company, Inc. ("We'' or "Us'') warrants to the original purchaser only ("You'' or "Your") that the Roughneck product purchased will be free from material defects in both materials and workmanship, normal wear and tear excepted, for a period of one year from date of purchase. The foregoing warranty is valid only if the installation and use of the product is strictly in accordance with product instructions.
Distributed by: Northern Tool & Equipment Company, Inc. Burnsville, Minnesota 55306 www.northerntool.