Product Manual

Page 11 of 17
electrical shock, use extra care when connecting the pump to power.
Avoid prolonged skin contact with petroleum fuels. Use protective goggles, gloves and aprons in
case of splashing or spills. Change saturated clothing and wash skin promptly with soap and
water.
Wear the proper protective gear including ANSI Z87.1 compliant safety goggles while operating.
This product should not be used for fluid transfer into an aircraft. This product is not suited for use
with fluids for human consumption or fluids containing water.
Extreme operating conditions with working cycles longer than 30 minutes can cause the motor
temperature to rise, thus damaging the motor itself. Each 30-minute working cycle should always
be followed by a 30-minute power-off cooling phase.
Use PTFE tape on all pipe threads.
Do not exceed the maximum by-passing time of 3 minutes.
Do not run dry past 30 seconds.
Burn hazard. To reduce the risk of burns, do not touch hot surfaces.
OPERATING CONDITIONS
Temperature: Min. -68°F Max.104°F (Min. -20°C / max +40°C)
Relative Humidity: max 90%
FLUID COMPATIBILITY
These products are compatible with the following fluids:
Gasoline, Diesel, Kerosene, and Mineral Spirits
CAUTION
Do NOT use with other fluids without consulting manufacturer.
If using flexible tubing, attach the ends of the tubing to the tanks. In the absence of an
appropriate slot, solidly grasp the delivery tube before beginning dispensing.
Before starting the pump make sure that the delivery valve is closed (dispensing nozzle or line
valve).
Turn the ON/OFF switch to ON. The by-pass valve allows functioning with the delivery closed for
only brief periods.
Open the delivery valve, solidly grasping the end of the tubing.
Close the delivery valve to stop dispensing.
When dispensing is finished, turn off the pump.
After Each Use
WARNING