User guide
  RN Commands Version 4.25, 11/1/2007 Page 17 of 25   
 809 University Avenue • Los Gatos, CA 95032 • 1-(408) 395-6539 • info@rovingnetworks.com 
www.rovingnetworks.com 
5  Command Quick Reference 
SET COMMANDS              FACTORY SETTING 
S7,<1,0>    -  7 bit data mode enable/disable      0= disabled 
SA,<1,0>    - Authentication enable/disable        0= disabled 
SB,<timer>   - Send BREAK          Not Applicable 
SC,<hex word>  - Service Class          0x0000= unknown 
SD,<hex word>  - Device Class           0x1F00= undefined 
SE,<1,0>    - Encryption enable/disable         0=disabled 
SF,1    - Factory Defaults 
SI,<hex word>  - Inquiry Scan window         0x0200 
SJ,<hex word>  - Page Scan window          0x0200 
SL,<E,O,N>   - Parity            N=None 
SM,<0,1,2,3>   - Mode (0=Slave, 1=mstr,2=trig, 3=auto)    0=Slave 
SN,<text>    - Name            FireFly-xxxx 
SO,<text>    - Connect/Disconnect Status String      NULL= no status string 
SP,<text>    - Pin Code            1234 
SR,<adr>    - Remote Address (SR,Z to remove)      NONE SET 
SS,<text>    - Service Name          SPP 
ST,<num>    - Config Timer          60 seconds 
SU,<rate>    - Baudrate            115K 
SW,<hex>    - SNIFF rate            0x0000=disabled 
SX,<1,0>    - Bonding            0=disabled 
S~,<0-3>    - Profile setting 0=SPP, 1=DCE, 2=DTE, 3=MDM  0 = SPP  
SZ,<num>    - Raw Baudrate           
GET, DISPLAY COMMANDS 
D     - Basic Settings 
E     - Extended Settings 
O     - Other Settings 
G<X>    - Stored setting 
H     - Help 
GB     - BT Address 
GK     - Connection Status 
G&     - I/O Ports 
V     - Firmware version 
ACTION COMMANDS 
C,<address>  - Connect, optional address, if no address, use stored remote address. 
CT<address>,<t>- Connect, required address, optional disconnect timer in ¼ seconds. 
F,1 - Enter Fast data mode, end configuration immediate. 
I,<time>,<cod> - Device Scan Inquiry, time in seconds, optional cod = class of device filter, 0=all 
IN<time>,<cod>- Device Scan Inquiry, returns NAMEs. 
IR<time> - Device Scan Inquiry, fixed cod=0x001F00 to find Roving devices. 
IS<time>  - Device Scan Inquiry, fixed cod =0x0055AA to find instant cable pairs. 