0102 095 50721 LFE MKII ROYAL BELMONT USERS (Pages 2-3)/ INSTALLATION (Pages4-8) AND SERVICING INSTRUCTIONS THIS CAT I2H APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER
'(6&5,37,21 86(56 ,16758&7,216 This Royal Cozy Fires Inset Live Fuel Effect gas fire has been developed to give a realistic coal burning appearance with the instant control and convenience of gas. The fire has been constructed to enable it to be installed into most applications where the warmth and comfort of an open fire with high radiant and convection heat is required.
4. Depress the gas control slightly and turn clockwise until the indicator mark is opposite to the large flame symbol. The burner will now run at its maximum rate. 5. To turn the appliance ‘off’, return the control to the ‘off’ position. 6. If for any reason the fire cuts out, return the control knob to the ‘off’ position and wait 3 minutes before relighting.
,167$//$7,21 $1 6(59,&,1* ,16758&7,216 7+( )2//2:,1* 6(&7,21 /,676 7+( ,167$//$7,21 5(*8/$7,216 $1' 5(48,5(0(176 All gas appliances must be installed by a competent person in accordance with the current Gas Safety (Installation and Use) Regulations 1994 (as amended) or the rules in force and in accordance with the manufacturers instructions, failure to do so could lead to prosecution The following are the relevant Codes of Practice and British Standards.
In most installations a back panel will be required, this will also need a minimum fire resistance rating of Class O (100 C). Check that the chimney and flue structure are sound and conform to the following flue requirements: 1. A conventional brick or stone chimneys with a minimum effective cross sectional dimension of 225x225 mm.
,167$//$7,21 86,1* $ ',$0(7(5 0(7$/ )/8( %2; IMPORTANT: Restrictor plates must be removed. See Fig 15. When the metal flue box is to be built-in as a false chimney-breast using timber stud work with a plasterboard facing, the metal flue box should be enveloped with insulation material such as Rockwool or similar to prevent a build-up of heat within the structure.
',60$17/,1* 7+( ),5( 35,25 72 ,167$//,1* The lower front panel assembly is removed by lifting upwards and pulling forwards. Remove the canopy to gain access to the Bezel or (Goal post trim) securing screws. The canopy is held in position by dimpled spring clips on both the side flanges, remove by exerting an even pull forward. See Fig 11. Remove the outer bezel/Goal post trim by unscrewing the four M4 taptite screws on the inner flanges and the four No 8 self tapping screws in the corners.
&+(&.,1* 23(5$7,21 2) ),5( Turn on the Gas supply at the meter and to the appliance at the isolating cock. Purge the air to the appliance. Rotate the control knob to the ignition position, depress the control and push the piezo to ignite the pilot. Check that the electrode is sparking between the tip of the thermocouple and continue until a pilot ignition is established.
0$,17(1$1&( $1' 6(59,&,1* *(1(5$/ $ 5(029$/ 2) '(%5,6 25 6227 '(326,76 Allow the appliance to cool sufficiently before removing all of the coals and firebed components for cleaning purposes. Once all the ceramics are removed from the firebed check that no debris is located in the burner slots (both front and rear). If any debris is present it may easily be removed by using a small piece of thin cardboard to ease out any foreign matter. Be sure to remove the cardboard after use.
6+257 3$576 /,67 For spares contact the manufacturer at the address below. DESCRIPTION Piezo Igniter Oxy-Pilot Burner Assy (SIT) Control Knob Control Valve Main Injector Stereomatic Coal Support Burner Inserts (2) Front Coal Mould Set of Coals Fibre Back Panel CROSSLEE No 40245 42313 40232 42143 42168 42981 42952 40481 42937 42953 GC No 397 686 170 014 HEAT INPUT 18,500 Btu/h 5.