Service manual

05-50
Fix the dowels in the crankcase and
carefully fix the motor with housing
starter drive. Apply LOCKTITE 5699
RTV silicon liquid gasket on the
joint face.
Fix the 4 Allen screws of housing
starter drive and tighten (Torque
0.6 KG-M).
Fix the main cable on the starter
motor on tighten. Insert rubber boot
properly.
Fix the E-Start motor cover.
Fix the E-Start motor with 2 allen
bolts (Torque 1 KG-M) along with
earthing cable.
NOTE : Apply LOCKTITE 577 thread seal-
ant to mounting bolts to avoid oil seepage
if any.
Assemble spacer (distance washer)
on Crankshaft LH.
CAUTIONCAUTION
CAUTIONCAUTION
CAUTION
::
::
:
This double stepped
faceshould be inside.