Owner’s Manual Portable Air Conditioner ARP-5008 ARP-5010 Royal Sovereign International, Inc. Please read and retain these instructions. To register your product, please go to www.royalsovereign.
Thank you for purchasing the Royal Sovereign Portable Air Conditioner, ARP-5008 / ARP-5010. This manual will provide you with safety information, instructions for optimal use, and proper care and maintenance for your product. Please read this manual carefully before operating. CONTENTS 2 SAFETY INSTRUCTIONS.……….................................................................................... 3 PRODUCT VIEW.……………………................................................................................
SAFETY INSTRUCTIONS When using this appliance follow these safety precautions to reduce risk of fire, electric shock, or injury. WARNING Electrical Safety 1. 2. 3. 4. 5. 6. 7. 8. 9. For your safety, this appliance should be properly grounded on a level surface indoors. The appliance should be placed near an electrical outlet so that the outlet is easily accessible. Make sure the voltage meets the appliance’s electricity requirements (115V/60Hz, 15 amps or more).
PRODUCT VIEW 1. 2. 3. 4. 5. 6. 7. 1. 2. 3. 4. 5. 6. (included) 4 SPEED button TEMPERATURE + button MODE button TIMER button TEMPERATURE – button POWER button Rear cover Air inlet Front cover Operation panel Castor wheels Power line Air inlet 1. 2. 3. 4. 5. 6. 7.
Installation Part 1: Placement • • Place the air conditioner on a flat surface and near a power supply outlet at least 12 in. (30 cm.) away from any wall or object that could block the airflow (See Fig.7). Socket wiring should be in accordance with the local electric safety requirements. Part 2: Exhaust Hose Installation • • • Twist both ends of the exhaust hose into the square fixing clip and the flat fixing clip. Insert the square fixing clip into openings at back of the air conditioner (see Fig.8).
PRODUCT OPERATION BEFORE PLUGGING IN THE UNIT TO A POWER SOURCE: 1. Let the appliance stand upright for about 2 hours. This will reduce the chance of malfunction in the cooling system from possible mishandling during delivery. 2. Check to make sure the rubber drain plugs are securely plugged into the drain ports on the back of the unit to prevent water leaks. 3. Check to make sure the exhaust hose has been installed properly (See Installation page 5). 4.
PRODUCT OPERATION Temperature Settings: Celsius to Fahrenheit (or Fahrenheit to Celsius) • To change press temp + and temp - simultaneously. Cooling operation • • • Press the “Mode” button until the “Cool” icon appears. Press the “Temp +” or “ Temp -” button to select a desired room temperature (60-90°F/16-31°C). Press the “Fan Speed” button to select wind speed. Dehumidifying operation • Press the “Mode” button until the “Dehumidify Indicator Lamp” blinks.
Machine Maintenance WARNING: Before maintenance, turn the power switch off and disconnect the power cord from the wall. Drainage The internal water tank in the air conditioner has one water level safety switch that controls water level. When the water level reaches an anticipated height, the water full indicator lamp lights up. NOTE: If water pump is damaged, drainage can be performed both manually and continuously. To drain manually: 1. 2. 3. 4. Turn off the power to the unit and unplug.
Machine Maintenance WARNING: Before maintenance, turn the power switch off and disconnect the power cord from the wall. If the unit will not be used for a long time: • Drain the air conditioner (See page 8). • After draining, keep the air conditioner running on FAN mode for at least 8 hours to dry the unit completely to prevent mold. • Pull out the power supply plug and wrap around power cord hooks. • Remove the batteries from the remote control before storage. • Clean the air filter.
TROUBLESHOOTING In case of problems, first turn off the air conditioner and disconnect from the source of electricity. Symptom Unit does not start when pressing power button Solutions • • • • • • • Reset the power plug. Wait 3 minutes and try to run the unit again. Drain the water tank (see Maintenance page 8). If the room temperature is lower than the set temperature in cooling mode, the unit will not run.
SPECIFICATIONS MODEL ARP-5008 ARP-5010 Cooling Capacity 8,000 BTU ASHRAE 10,000 BTU ASHRAE 4,000 BTU DOE 5,000 BTU DOE Room Size (Sq. ft.) Up to 300 Up to 400 Voltage / Frequency 115V / 60 Hz 115V / 60 Hz Standard Cooling Input Power 860W 1050W Operating Sound Level 65 dB 65 dB Dehumidifier Capacity 40 Pints (19.2 L) per Day 40 Pints (19.2 L) per Day Air Flow Volume 320 m3h 320 m3h Fan Speeds 2 2 Refrigerant R410A R410A Unit Dimensions (W x D x H) 13”W x 11”D x 26.
ONE YEAR LIMITED WARRANTY Royal Sovereign International, Inc. warranties this product to be free from defects in material and workmanship to the original purchaser only as outlined below. Parts: Replacement of defective parts for 1 year from the date of customer purchase. Compressor: 5 year warranty from the date of customer purchase. Royal Sovereign will supply a replacement compressor (parts only), free of charge. Labor: 1 year from the date of end user purchase.