Specifications

September 2012 Page
32
OVER HEATING
1) Manually turn o the draft fan at the fan switch (place switch in OFF position).
2) The pump must have power to remove heat from the appliance.
3) Turn the thermostats fully up in the structure being heated by boiler to remove heat from the appliance as fast
as possible.
4) Allow the appliance to cool down.
5) Once the unit has cooled down:
Determine and correct the cause of the overheating
Re ll the system if necessary
CHIMNEY FIRE
1) CALL 911 – INDOOR UNITS ONLY.
2) EVACUATE THE BUILDING. INDOOR UNITS ONLY
3) Manually turn o the draft fan at the FAN switch and close damper plate.
4) Leave the doors securely closed.
5) DO NOT TURNOFF THE SWITCH MASTER. The pump must have power to remove heat from the appliance.
LOSS OF ELECTRICAL POWER
1) Shut blower damper plate fully.
2) Restore Electrical Power.
3) If electrical power is o for a long duration, the appliance may over heat. Remove fuel and coals from the
re box. Place removed fuel away from combustibles.
EMERGENCY ACTIONS