Specification

CONFIGURATIONS
• Upflow / Horizontal
• Downflow
HEAT EXCHANGER DESIGN
• Aluminized steel primary heat exchanger with crimped non-
welded construction
• AL 29-4C Stainless steel secondary heat exchanger
BURNER
• Aluminized steel inshot burners for smooth ignition
CABINET DESIGN
• Compact 33” height
• Standardized widths for easy coil fit
AIR DELIVERY SYSTEM
• Multi-speed high efficiency (constant torque) blower motor
• Easily removable slide out blower design
• Enhanced cooling SEER ratings when applied with properly
matched cooling equipment.
CONTROLS
• Single stage gas valve
• Durable silicon nitride ignitor
• Self diagnostics saves last 10 fault codes regardless of power
interruption
• Control features electronic air cleaner and humidifier terminals
VENTING
• Designed certified for direct (2-pipe) and non direct (1-pipe)
applications
• Easily vented with PVC pipe
INSTALLATION FEATURES
• Left or right utility connection
• Design certified for direct and non-direct vent applications
• Zero step horizontal conversion
• Removable floor base (upflow / horizontal units) for bottom
return air
• Complies with California’s South Coast Air Quality
Management district Low NOx requirements
WARRANTY
10 year limited parts warranty / lifetime heat exchanger warranty
available. See limited warranty document for details.