Installation Guide

507052-04Page 48 of 53 Issue 1727
Blower Performance
Model Temp Rise
Speed
Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting “D” Setting “C” Setting “B” Setting “A”
A95DF2V045B12S
95G2DF045BV12
High Fire
35 - 65
+ 735 830 1015 1210
Normal 680 750 930 1070
- 625 695 835 1000
Low Fire
20 - 50
+ 705 780 975 1110
Normal 655 730 890 1055
- 595 670 790 960
Cooling
Stage
Speed
Adjustment
Cooling CFM @ 0 - 0.8” w.c.
Setting “D” Setting “C” Setting “B” Setting “A”
2nd Stage
+ 895 1050 1210 1360
Normal 805 965 1105 1250
- 735 865 1000 1130
1st Stage
+ 640 755 850 975
Normal 580 695 780 880
- 545 645 720 795
Model Temp Rise
Speed
Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting “D” Setting “C” Setting “B” Setting “A”
A95DF2V070B16S
95G2DF070BV16
High Fire
35 - 65
+ 1110 1305 1430 1700
Normal 995 1175 1315 1520
- 880 1055 1170 1365
Low Fire
25 - 55
+ 860 1020 1140 1340
Normal 795 910 1030 1230
- 680 825 910 1085
Cooling
Stage
Speed
Adjustment
Cooling CFM @ 0 - 0.8” w.c.
Setting “D” Setting “C” Setting “B” Setting “A”
2nd Stage
+ 1110 1340 1575 1800
Normal 995 1230 1420 1650
- 880 1085 1290 1460
1st Stage
+ 740 915 1055 1255
Normal 660 820 940 1120
- 575 735 850 995