Installation Guide

507052-04 Page 49 of 53Issue 1727
Model Temp Rise
Speed
Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting “D” Setting “C” Setting “B” Setting “A”
A95DF2V090C20S
95G2DF090CV20
High Fire
35 - 65
+ 1395 1555 1695 1825
Normal 1275 1395 1585 1670
- 1145 1265 1405 1525
Low Fire
20 - 50
+ 1130 1230 1365 1475
Normal 1040 1130 1250 1340
- 910 1025 1130 1210
A95DF2V090C20S
Cooling
Stage
Speed
Adjustment
Cooling CFM @ 0 - 0.8” w.c.
Setting “D” Setting “C” Setting “B” Setting “A”
2nd Stage
+ 1335 1600 1750 1980
Normal 1225 1450 1630 1830
- 1120 1270 1450 1660
1st Stage
+ 955 1115 1265 1450
Normal 855 1005 1150 1285
- 750 890 1060 1170
Model Temp Rise
Speed
Adjustment
Heating CFM @ 0 - 0.8” w.c.
Setting “D” Setting “C” Setting “B” Setting “A”
A95DF2V110C20S
95G2DF110CV20
High Fire
35 - 65
+ 1595 1795 1955 2140
Normal 1450 1615 1795 1975
- 1290 1460 1610 1795
Low Fire
25 - 55
+ 1165 1305 1465 1625
Normal 1055 1185 1315 1475
- 930 1070 1180 1320
Cooling
Stage
Speed
Adjustment
Cooling CFM @ 0 - 0.8” w.c.
Setting “D” Setting “C” Setting “B” Setting “A”
2nd Stage
+ 1335 1585 1790 2010
Normal 1220 1440 1630 1865
- 1100 1275 1475 1680
1st Stage
+ 920 1095 1265 1440
Normal 830 965 1130 1290
- 735 860 1035 1155