INSTALLATION SHEET
OSMV OUTDOOR STREAMING MOTION VIEWER
Tilt Tamper
The OSMV MotionViewer can detect
manipulation thanks to its built-in electronic
accelerometer.
This device can detect shocks, movements,
wall or cover tamper but also changes in its
orientation.
When a movement of the OSMV is detected,
the LED lights up for 3 seconds.
When it is armed for the first time, the OSMV registers its position in space. If its orientation is
significantly changed on its transverse or longitudinal axis, a tamper alarm is sent to the panel. As for
every Videofied device, the tamper is active 24/7.
If the detector is moved, the TAMPER notification will be displayed on the keypad the next time the
system is armed. Press OK/YES to acknowledge that notification and confirm the detector new
position. If the TAMPER event is set as ALARM/END, a tamper restoral event is sent to the panel.
Rotation axe longitudinal
Rotation axe transversal
Wired inputs/output
The OSMV MotionViewer has 3 built-in wired inputs. With these inputs, other detection systems can be
associated with the OSMV.
IN1 and IN2 inputs : Normally open wired inputs. These inputs are enabled when the OSMV is armed.
When triggered, an INTRUSION event is sent to the panel and the OSMV captures a video.
IN3 input : Normally open wired input. This input is enabled 24/7. When triggered, a TAMPER event is sent
to the panel.
The OSMV also has one built-in wired output. This output can activate a wired system when the OSMV
infrared detection is triggered.
OUT output : 24 V/100 mA open drain contact. When the OSMV is triggered, the output contact closes for 3
seconds and opens.
Inputs/outputs wiring
Two drilling punch marks are visible on the OSMV
case. One under the case and one inside the box on
the bottom right.
Drill a hole in one of these punch marks to pass
the wire through and connect the inputs/outputs
terminal.
IMPORTANT :
Once the wire is connected, protect the inside of
the case with a silicone watertight seal.
Punch mark
Tilt tamper disabling (only for OSMV version 07.06.04.XX and later)
Tamper disabling
The OSMV Motionviewer must be deleted from the panel memory
to disable tamper.
1. Delete the OSMV from the device configuration menu.
2. Press and hold the OSMV initialization button for 5 seconds. The
red LED will turn on for 2 seconds to confirm the setting.
3. Pair the OSMV back with your panel.
Tamper re-enabling
The tamper re-enabling procedure is the same
1. Delete the OSMV from the device configuration menu.
2. Press and hold the OSMV initialization button for 5 seconds. The
red LED will turn on for 2 seconds to confirm the setting.
3. Press and hold the init button for 5 seconds. The red LED will turn
on for 2 seconds, off for half a second and back on for 2 seconds.
4. Pair the OSMV back with your panel.