User's Manual

22
W and WIP Panel www.videofied.com
The W panel can be configured to enable or disable the transmission of specific
events like alarms or malfunctions.
The installer can modify the default sending settings for those events, although it
will end the EN50131 standard compliance.
5. Transmitted events list
How to modify the transmission state
At initial programming, right aer the PERIODIC TEST CALL step:
Aer initial programming, using a remote keypad :
Example :
If the monitoring station system is set to receive arms and disarms, the ARM / DISARM parameter must be
changed from NOT TRANSMITTED to ALARM / END.
Press
OK or YES
to access EVENT TRANS. MODIFICATION menu.
CODE/STATE
MODIFICATION
Use the arrows to access :
CONFIGURATION (level 4) > CONFIGURATION MONITOR. STATION > MONITORING PARAMETERS > EVENT TRANS. MODIFICATION
Then use the arrows to determine the event to modify. Press
OK or YES
to edit.
These are the default transmitted events :
DEVICE (intrusions)
ALERT (Panic Buttons)
PANEL LOW BATT.
TAMPER
DEVICE LOW BATT.
PERIODIC TEST
DURESS CODE
FIRE
MEDICAL ASSIST.
ETHERNET CABLE
AC POWER LOSS (AC Power supply)
The following events are not sent by default :
PANEL RESET
PHONELINE FAULT
RADIO JAMMING
SUPERVISION
5 WRONG CODES
ALARM CANCEL
ARM/DISARM (On/O)
ZONE BYPASS (bypass function enabling/dsiabling)
SWINGER SHUTDOWN
There is 3 different transmission states :
ALARM : event transmitted upon occurrence
ALARM/END : event is transmitted on occurrence and on event restoral
NOT TRANSMITTED : event is not transmitted, however it will appear on the keypad.