User guide

Aries Reference Manual Section 2 – Viewing and Analysing Data
Radio Systems Information Ltd. Page 30
Figure 34: Warnings configuration
The following parameters should be set for each warning:
Parameter Comment
Warning Text
Enter the text that will be sent in the SMS message when
the warning is triggered
Check Period
Select the time period for checking the parameter
Time Delay after
sending warning
Select the time period that must elapse after a warning
before another warning for the same parameter is sent
again. This prevents repeated SMS and/or email being sent
if the parameter continues to trigger the warning
GSM Number
Enter the GSM number that the warning SMS should be
sent to. If left blank then no SMS is sent. Enter multiple
numbers by separating them with commas.
Email Enter the email address that the warning message should
be sent to. If left blank then no email is sent. Enter multiple
email addresses by separating them with commas.
Warning Type
There are 8 types of warning:
- Check site frequency against site list
this checks that the base site frequency being reported for
each event is in the list of frequencies expected for that
base site. This guards against a common problem where a
base-site is re-configured to work on a different frequency
without re-configuring the rest of the network which can
lead to unexpected co0channel interference