Operating instructions
31
It’s Under Control
®
If you are having problems with your T3-V+ Universal System Controller, 
please read the information below before contacting technical support.
If you continue to have problems, see Chapter 6 for more information on 
contacting RTI technical support.
DISPLAY IS DIM, BLANK OR UNREADABLE
  Make sure the battery pack connector is attached properly and the 
battery is charged.
  Try adjusting the backlight level from the Control Panel page (Refer to 
Chapter 3 for more details). By nature, the contrast of an LCD screen 
changes with temperature, so if the remote is cold the display will be 
dark and will return to normal as it warms.
USB COMMUNICATIONS PROBLEMS
  Verify that your PC is running Windows XP
®
 or higher.
  Verify that the T3-V+ USB driver was installed the rst time the T3-V+ 
was connected to your PC.
  Verify that the T3-V+ is present in the Device Manager within the 
Windows
®
 Control Panel.
  Make sure you are using the programming cable that was supplied by 
RTI and that both ends are connected securely.
  Make sure the PC detects the presence of the T3-V+. If it doesn’t, 
unplug the USB cable, wait for about ten seconds, and plug it in again.
  If the download fails after some data has been transferred, try re-
sending the program.
IR CODE PROBLEMS
  If you are using an IR repeater system, make sure it is working 
correctly with the original OEM remote. If not, you will need to 
troubleshoot the IR repeater system.
  If you are still having problems, try adjusting the IR code “Minimum 
Repeats” value in the Integration Designer
®
 programming software.
  If the IR code is executed inside a macro that contains multiple IR 
codes, try inserting a small time delay before the problem code. If 
there already is a delay, try increasing it.
CHAPTER 5  |  TROUBLESHOOTING