Specifications

RTS 2nd Generation SERVO AMPLIFIER
65
PVD 3487 GB 03/2004
7.4.11 dc voltage calibration (RB)
Resistor RB is used to adapt limit values: MAX U, MIN U, tripping of supply voltage recovery.
The standard values are as follows :
SERVO AMPLIFIER
MODEL
Input
voltage
VAC (1)
DC
voltage
Max
voltage
Min
voltage
Dissipation resistance
On limit Off limit
V V
RB
k
RTS 3/10 - 40
RTS 10/20 - 60
RTS 12/24 - 130
20/40 - 130
RTS 12/24 - 48
RTS 12/24 - 24
RTS 16/32 - 190
32
48
100
48
24
135
43
65
135
48
24
190
57
86
179
64
34
240
27
40
83
30
16
112
53
79
164
-
-
221
50
75
156
-
-
210
200
100
(1) Remark : The RTS servo amplifier may be used with supply voltages different from
the standard values.
e.g. RTS 10/20-40 with 32 V supply
RTS 16/32-140 with 110 V supply
Please ask for details.