DV-MUX3 ADAPTIVE MULTIPLEXER FOR VOICE, FAX AND DATA Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications. No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications. No representation or warranties for fitness for any purpose other than what is specifically mentioned in this manual is made either by RAD Data Communications or its agents.
Safety Warnings The exclamation point within a triangle is intended to warn the operator or service personnel of operation and maintenance factors relating to the product and its operating environment which could pose a safety hazard. Always observe standard safety precautions during installation, operation and maintenance of this product. Only a qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this instrument.
Regulatory Information FCC-15 User Information This equipment has been tested and found to comply with the limits of the Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Declaration of Conformity Manufacturer’s Name: RAD Data Communications Ltd. Manufacturer’s Address: 12 Hanechoshet St. Tel Aviv 69710 Israel declares that the product: Product Name: DV-MUX3 Conforms to the following standard(s) or other normative document(s): EMC: Safety: EN 55022 (1994) Limits and methods of measurement of radio disturbance characteristics of information technology equipment.
TABLE OF CONTENTS Page CHAPTER 1. 1-1. 1-2. 1-3. CHAPTER 2. INTRODUCTION FUNCTIONAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . Purpose and Main Features . . . . . . . . . . . . . . . . . . . . . . Voice/Fax Channel Features . . . . . . . . . . . . . . . . . . . . . . Data Channel Features . . . . . . . . . . . . . . . . . . . . . . . . Main Link Characteristics . . . . . . . . . . . . . . . . . . . . . . . Dial-up Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TABLE OF CONTENTS (Cont’d) Page . . . . . . . . . . . . . . . . . 2-7 2-7 2-8 2-9 2-10 2-10 2-11 2-11 2-12 2-12 2-12 2-12 2-13 2-13 2-13 2-14 2-14 3-1. DV-MUX3 FRONT PANEL CONTROLS AND INDICATORS . . . . . . . . . Special Diagnostic Indications . . . . . . . . . . . . . . . . . . . . . . . Configuration Error Indication . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-2 3-3 3-2. PREPARATION FOR OPERATION, GENERAL . . . . . . . . . . . . . . . 3-3 3-3. OPERATING INSTRUCTIONS .
TABLE OF CONTENTS (Cont’d) Page APPENDIX A. CONNECTION DATA A-1. SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 A-2. MAIN LINK AND DATA CHANNEL INTERFACES Interface Connectors . . . . . . . . . . . . . . X.21 Pin Allocations . . . . . . . . . . . . . . V36/RS-449 Interface Adapter Cable . . . . . RS-530 Interface Adapter Cable . . . . . . . . V.35 Interface Adapter Cable . . . . . . . . . V.24/RS-232 Interface Adapter Cable . . . . . . . . . . . .
LIST OF ILLUSTRATIONS Figure Title Page 1-1. 1-2. Typical DV-MUX3 Application in an SNA Link . . . . . . . . . . . . . . . . . . . Typical DV-MUX3 Application in an Inter-LAN Link . . . . . . . . . . . . . . . . 2-1. 2-2. 2-3. 2-4. 2-5. 2-6. 2-7. DV-MUX3, Identification of Internal Modules . . . DV-MUX3, Identification of Main Board Jumpers . Voice Channels Module Switches . . . . . . . . Selection of Transmit and Receive Levels . . . . DV-MUX3-E&M, Internal Settings . . . . . . . .
CHAPTER 1. INTRODUCTION Contents Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . Typical Applications and System Design Considerations . . . . . . . Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . Page 1-1 1-7 1-14 1-1. FUNCTIONAL DESCRIPTION Purpose and Main Features The DV-MUX3 is a versatile adaptive time division multiplexer (TDM) for voice, fax, and data.
CHAPTER 1 - INTRODUCTION ° The other non-adaptive mode provides the user with access to all the link bandwidth that is not used by the voice channel. In this mode, the data channel can serve data terminal equipment capable of operation in accordance with the rate of the clock signals provided by the DV-MUX3, including operation at data rates which are not necessarily based on the n × 75 bps scheme.
FUNCTIONAL DESCRIPTION The FXO and FXS options are usually operated in a link, with the FXO interface at the PABX side, and the FXS interface on the subscriber’s side. In addition, two FXS interfaces can also be operated in a link, to provide PLAR (Private Line with Auto-Ring) telephone service. The E&M interface is usually used to connect trunk lines of two PABXs. In this case, two E&M interfaces are operated in a link.
CHAPTER 1 - INTRODUCTION The following control lines are used on the main link interface: • The RTS line, which is asserted as long as the DV-MUX3 is powered. • The DTR and RI lines, used only in the dial-up mode. Dial-up Mode The dial-up mode allows the DV-MUX3 to operate over the Public Switched Telephone Network (PSTN), using dial-up modems to transmit the main link data over standard PSTN lines. The dial-up mode is available only when the main link interface is V.35 or RS-232.
FUNCTIONAL DESCRIPTION ° For a voice channel equipped with E&M interface, the channel control signal generated by that channel indicates detection of an M signal. The control signal received by that channel (E signal) indicates the reception of subscriber off-hook at the remote FXS module or detection of the M signal at the remote E&M module.
CHAPTER 1 - INTRODUCTION • Front panel indicators show main link synchronization status, transmit and receive activity on any desired channel, and activation of a test loop. In addition, the front panel indicators also indicate failures in the power-up selftest, configuration errors, and fault conditions related to the main link clock signals. General Features 1-6 The DV-MUX3 can be ordered for AC operation (100, 115, or 230 VAC) or for -48 VDC operation, and has very low power consumption.
TYPICAL APPLICATIONS AND SYSTEM DESIGN CONSIDERATIONS 1-2. TYPICAL APPLICATIONS AND SYSTEM DESIGN CONSIDERATIONS Typical Applications This section provides examples of applications that use the specific capabilities of the DV-MUX3. Typical DV-MUX3 Application in an SNA Link Figure 1-1 shows a typical application for a DV-MUX3. This application shows how an organization can use the DV-MUX3 to connect privileged telephone subscribers located in another city, e.g.
CHAPTER 1 - INTRODUCTION • The second voice channel of the DV-MUX3 is used for PLAR service, and is connected directly to the subscriber’s telephone set. This voice channel uses an FXS interface. • At the branch office, the two local subscriber sets are connected to the two voice channels of the DV-MUX3. These voice channels use the FXS interface. The first voice channel (connected at the main office to a subscriber line of the PBX) is used for voice/fax transmission.
TYPICAL APPLICATIONS AND SYSTEM DESIGN CONSIDERATIONS • For a voice channel with FXO interface: the detection of incoming ringing at the voice channel interface. • For a voice channel with E&M interface: the detection of an active M signal. Figure 1-2.
CHAPTER 1 - INTRODUCTION This symmetry reflects the way voice channels are used (either side can initiate a call to the other side). • Valid connection requests originating from the data channel can be made only by the slave DV-MUX3, because the DV-MUX3 dial-up mode is designed to operate asymmetrically with respect to the data channel. This means that a request for connecting the link to the other DV-MUX3 can be made only by the slave DV-MUX3.
TYPICAL APPLICATIONS AND SYSTEM DESIGN CONSIDERATIONS Control over the Main Link Modems The control of the dial-up modems serving the main link is made by means of the DTR line of the DV-MUX3 main link interface. Assuming that the modems were configured as explained above, the sequence for setting up and for disconnecting the link between two DV-MUX3 units is as follows: • The link is in the disconnected state when no user traffic is present.
CHAPTER 1 - INTRODUCTION Table 1-1. Adaptive and Non-Adaptive 1 Modes, Data Channel Bandwidth as a Function of Voice Channel and Main Link Rates Data Channel Bandwidth vs. Voice Channel Digitizing Rate Main Link Data Rate Idle Voice Channels (Adaptive 4.8 kbps 6.4 kbps 7.2 kbps 9.6 kbps 12.8 kbps 4.8 kbps 6.4 kbps 7.2 kbps 9.6 kbps 12.8 kbps mode only) One Voice Channel Two Voice Channels 9.6 kbps 4 kbps 2.4 kbps 1.6 kbps – – – – – – – 8.8 kbps 12 kbps 6.4 kbps* 4.8 kbps 4.0 kbps 1.
TYPICAL APPLICATIONS AND SYSTEM DESIGN CONSIDERATIONS System Timing Considerations This section explains the timing modes and clock rates available for the main link of the DV-MUX3, and for its data and voice channels. Main Link Timing The main link transmit and receive paths of the DV-MUX3 require external receive and transmit clock signals derived from the network clock. The transmit and receive clock must be derived from the same source.
CHAPTER 1 - INTRODUCTION 1-3. TECHNICAL SPECIFICATIONS General Function Three-channel adaptive multiplexer Multiplexing Method Bit-interleaved Time Division Multiplexing (TDM) Management and Supervision Overhead – 0.8 kbps for main link data rates of 9.6 to 32 kbps – 1.6 kbps for data rates of 48 to 128 kbps – 3.2 kbps for data rates higher than 128 kbps Main Link Characteristics Data Rate 9.6 to 256 kbps, automatically recognized Timing Externally clocked Interface Synchronous V.24/RS-232, V.
TECHNICAL SPECIFICATIONS Analog Characteristics (9.6 kbps) Nominal transmit level +2 to -13 dBm, independently adjustable for each channel in steps of 1 ±0.15dB Nominal receive level FXS, E&M FXO Independently adjustable for each channel in steps of 1 ±0.15dB +2 to -13 dBm +1 to -13 dBm Frequency response (referred to 1020 Hz) ±0.5 dB, 300-3000 Hz ±1.1 dB, 250-3400 Hz Signal-to-distortion @ 9.6 kbps (ITU-T Rec. G.712, G.
CHAPTER 1 - INTRODUCTION On-hook DC resistance More than 1 MΩ AC impedance 20 kΩ at 20 Hz, 70 Vrms Ring detect range >20 Vrms, 17 to 25 Hz Transformer isolation 3000 Vrms E&M Interface Signaling interface – EIA RS-464 Type I – Modified EIA RS-464 Type II, III, V (with -24V instead of -48V) – British Telecom SSDC5 Analog interface 4-wire or 2-wire interface, strap selectable AC impedance 600 Ω Transformer isolation 1500 Vrms Diagnostics Two push-buttons used for activation of remote loops a
CHAPTER 2. INSTALLATION Contents Page General . . . . . . . . . . . . . . . Unpacking . . . . . . . . . . . . . . Site Requirements . . . . . . . . . . DV-MUX3 Configuration Information Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-2 2-2 2-3 2-12 2-1. GENERAL The DV-MUX3 is delivered completely assembled.
CHAPTER 2 - INSTALLATION 2-2. UNPACKING A preliminary inspection of the equipment container should be made before unpacking. Evidence of damage should be noted and reported immediately. To unpack, place the container on a clean flat surface, cut all straps, and open or remove top. Carefully take out the DV-MUX3 and all the accessories packed in the container, and place them securely on a clean surface. Inspect the product for damage. Immediately report any damage. 2-3.
DV-MUX3 CONFIGURATION INFORMATION 2-4. DV-MUX3 CONFIGURATION INFORMATION General The DV-MUX3 contains several printed circuit boards, identified in figure 2-1: • Main board. This board contains most of the DV-MUX3 circuits. • Voice channels module. In accordance with your order, this module can include one or two voice channels. • Voice channel interface modules. Three types of voice channel interface boards are available: ° DV-MUX3-FXO for FXO interface. ° DV-MUX3-FXS for FXS interface.
CHAPTER 2 - INSTALLATION Opening DV-MUX3 Case The DV-MUX3 jumpers are located on its boards. The boards are attached to the rear panel. To reach the internal jumpers: • Disconnect all the cables connected to the DV-MUX3. • Unscrew the two large captive screws located on the rear panel. • Carefully pull the rear panel out. The internal boards will slide out together with the panel. The DV-MUX3 has several tall components which barely clear the top cover: make sure you do not damage these components.
DV-MUX3 CONFIGURATION INFORMATION Main Board Jumpers The user-selectable jumpers located on the main board of the DV-MUX3 are identified in figure 2-2. In addition to the jumpers identified in figure 2-2, the main board includes additional factory-set jumpers which must not be moved. Figure 2-2. DV-MUX3, Identification of Main Board Jumpers MODE Selection Jumper, J2 This jumper selects the DV-MUX3 bandwidth allocation mode, and its configuration mode.
CHAPTER 2 - INSTALLATION main link bandwidth is always fully utilized, however not all types of user equipment can support the dynamic changes in clock rate that occur in this mode. See Table 1-1 for the available data rates. N/ADPT1 The DV-MUX3 operates as a master, and uses the non-adaptive 1 allocation mode. In this mode, the DV-MUX3 determines the data rate of the data channel as in the adaptive mode, except that the bandwidth required by the voice channel is permanently allocated.
DV-MUX3 CONFIGURATION INFORMATION DTR Jumper, J11 This jumper is used to enable the dial-up mode. The dial-up mode can be enabled only when the DV-MUX3 main link interface uses the RS-232 interface. For other interfaces, the dial-up mode is not available, irrespective of the setting of this jumper. The jumper has two positions: CNTL When the RS-232 interface is selected, the dial-up mode is enabled.
CHAPTER 2 - INSTALLATION Figure 2-3. Voice Channels Module Switches VOICE2 Enable Switch, SW5 On DV-MUX3 units equipped with two voice channels, this switch allows the user to disable voice channel 2. By disabling voice channel 2, the bandwidth available to the data channel is increased. The switch has two positions: • DIS - voice channel 2 is disabled. • EN - voice channel 2 is enabled. The default setting is EN.
DV-MUX3 CONFIGURATION INFORMATION Level Adjustment Switches, SW1, SW2, SW3, SW4 These switches are used to select the nominal input and output levels of the voice channels: • SW1 selects the nominal output level of the voice channel 1 receive path. • SW2 selects the nominal input level of the voice channel 1 transmit path. • SW3 selects the nominal output level of the voice channel 2 receive path. • SW4 selects the nominal input level of the voice channel 2 transmit path.
CHAPTER 2 - INSTALLATION Voice Channel Interface Modules Only the DV-MUX3-E&M voice channel interface board requires internal settings that are used to select the signaling mode and the interface type, 2W or 4W. Figure 2-5 identifies the position of these switches. Figure 2-5. DV-MUX3-E&M, Internal Settings E&M Signaling Mode Selection The DV-MUX3-E&M module supports five E&M signaling modes: RS-464 Type I, II, III and Type V, and British Telecom SSDC5.
DV-MUX3 CONFIGURATION INFORMATION Figure 2-6. Equivalent Signaling Circuits 2W/4W Selection, Switch SW3 Switch SW3 selects the analog interface: 2W 2-wire interface 4W 4-wire interface Default setting is 4W. Internal Settings Procedure Refer to figures 2-1 through 2-6 and identify jumper and switch locations and settings. Change settings as required.
CHAPTER 2 - INSTALLATION • Insert the front side of the DV-MUX3 board into both card guides (grooves) on the internal side of the case walls, and then carefully slide the board in. Be careful to prevent damage to the tall components. If resistance is felt before the rear panel touches the case, pull the board out and then repeat the procedure. • Fasten the rear panel by fully screwing in the two large rear panel screws. 2-5.
CABLE CONNECTIONS WARNING AC Power Connection BEFORE POWERING UP this instrument and before connecting any other cable the protective earth terminals of this instrument must be connected to the protective conductor of the power cord. The power plug shall only be inserted in a socket outlet provided with a protective earth contact. The protective action must not be negated by use of an extension cord (power cable) without a protective conductor (grounding).
CHAPTER 2 - INSTALLATION Data Channel Connections The DV-MUX3 data channel interface is configured as a data communication equipment (DCE) interface, thereby allowing direct connection to data terminal equipment (DTE). The data channel connector is a 15-pin D-type female connector, wired in accordance with ITU-T Rec. X.21.
CHAPTER 3. OPERATING INSTRUCTIONS Contents DV-MUX3 Front Panel Controls and Indicators . . . . . . . . . . . . Preparation for Operation, General . . . . . . . . . . . . . . . . . . Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . Page 3-1 3-3 3-4 3-1. DV-MUX3 FRONT PANEL CONTROLS AND INDICATORS Table 3-1 lists the functions of the DV-MUX3 controls and indicators located on the front panel. The Item numbers in Table 3-1 correspond to the index numbers in figure 3-1. Figure 3-1.
CHAPTER 3 - OPERATING INSTRUCTIONS Table 3-1. DV-MUX3 Controls and Indicators Item Control or Indicator Function 1 PWR indicator Lights when the DV-MUX3 is powered 2 TEST indicator Lights steadily when a BERT test, tone injection, or a remote loop is active on the DV-MUX3. Flashes (0.5 second on/0.
PREPARATION FOR OPERATION, GENERAL Configuration Error Indication The flashing of the TEST indicator while the SYNC LOSS indicator is off indicates a configuration error. The configuration error indication is displayed under the following circumstances: • Bandwidth “overflow”: the total bandwidth assigned to the data and voice channels, including the link synchronization and supervision overhead, exceeds the main link data rate determined by measuring the link clock signal frequency.
CHAPTER 3 - OPERATING INSTRUCTIONS 3-3. OPERATING INSTRUCTIONS Preliminary Settings Release all the push-buttons. Turn-on The DV-MUX3 does not have a power switch, therefore it immediately starts operating when power is applied. To apply power, connect the DV-MUX3 power cable to its rear POWER connector, then plug the other end into a grounded mains outlet. When power is connected, the DV-MUX3 performs self-test. During self-test, all the indicators light for approximately 0.
OPERATING INSTRUCTIONS When the loop is no longer required, release the depressed push-button by pressing it again. The TEST indicator turns off. Refer to Chapter 4 for a description of the test loops. BERT Activation To activate the BERT test, set the SELECT switch to the DATA position, and then press the PATT push-button. The TEST indicator turns on, the TD indicator must light, and the RD/ERR indicator lights if errors are detected (ideally, the RD/ERR indicator should remain off during the test). 1.
CHAPTER 3 - OPERATING INSTRUCTIONS When tone injection can be stopped, release the depressed push-button by pressing it again. The TEST indicator turns off. Refer to Chapter 4 for a description of the tone injection. Turn-off 3-6 Disconnect the power cable from the mains outlet, and then from the DV-MUX3 rear power connector.
CHAPTER 4. DIAGNOSTICS Contents General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Description of Diagnostic Functions . . . . . . . . . . . . . . . . . . Troubleshooting Instructions . . . . . . . . . . . . . . . . . . . . . Page 4-1 4-2 4-5 4-1. GENERAL Three types of diagnostic functions are available: • Remote loopback. • BERT testing (available only on the data channel). • Tone injection (available only on the voice channels).
CHAPTER 4 - DIAGNOSTICS 4-2. DESCRIPTION OF DIAGNOSTIC FUNCTIONS General A test or loop is activated on the channel selected by the SELECT switch by depressing the corresponding DV-MUX3 front-panel push-button. As long as any test or loop is activated, the TEST indicator lights. To deactivate the test or loop, press the same push-button again. If this was the only active test or loop, the TEST indicator will turn off.
DESCRIPTION OF DIAGNOSTIC FUNCTIONS Remote Data Channel Loopback During a remote data channel loop, the local channel transmit data is multiplexed by the local DV-MUX3 and sent to the remote DV-MUX3. At the remote DV-MUX3, the data channel is demultiplexed, the receive data is looped back to the transmit path of the remote data channel, and then returned through the link to the local data channel as received data.
CHAPTER 4 - DIAGNOSTICS Figure 4-2.
TROUBLESHOOTING INSTRUCTIONS 4-3. TROUBLESHOOTING INSTRUCTIONS In case a problem occurs, refer to Table 4-1, identify the closest description of the trouble symptoms and perform the actions listed under “Corrective Measures” in the order given, until the problem is corrected.
CHAPTER 4 - DIAGNOSTICS Table 4-1. Troubleshooting Chart (Cont’d) No. Symptoms 5 TEST SYNC LOSS 6 7 8 4-6 flashes off Probable Cause Corrective Measures Configuration error Check for the following possible errors, and correct if necessary: – Both the local and remote DV-MUX3 are configured as slave units. – Both are configured as master units, and the parameters are different. – Both are configured as master units, and the MODE jumper settings are different.
APPENDIX A. CONNECTION DATA Contents Scope . . . . . . . . . . . . . . . . . Main Link and Data Channel Interfaces Voice Channel Interface . . . . . . . . DC Power Connector . . . . . . . . . Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 A-2 A-7 A-8 A-1. SCOPE This Appendix provides information on the type and pin allocation of the various DV-MUX3 interface connectors.
APPENDIX A - CONNECTION DATA A-2. MAIN LINK AND DATA CHANNEL INTERFACES Interface Connectors The main link and data channel interface connectors are 15-pin D-type female connectors. The following tables also present the direction of the signals in the main link and the data channel connectors. NOTE X.21 Pin Allocations When the selected interface is X.21, the connector is wired in accordance with ITU-T Rec. X.21. Connector pin allocations are listed in Table A-1. Table A-1.
MAIN LINK AND DATA CHANNEL INTERFACES V36/RS-449 Interface Adapter Cable The V.36/RS-449 interface adapter cable, CBL-KM-22/449, is terminated on the user’s side in a 37-pin D-type female connector, wired as listed in Table A-2. Table A-2. V.36/RS-449 Interface Adapter Cable DB-15 Interface Connector Pin DB-37 Connector Pin (User’s Side) Designation 1 1 2 Direction Function LINK DATA Shield – – Frame ground (shield) 4 SD(A) OUT IN TX data - A wire 3 7 RS(A) OUT N.
APPENDIX A - CONNECTION DATA RS-530 Interface Adapter Cable The RS-530 interface adapter cable, CBL-KM-22/530, is terminated on the user side in a 25-pin D-type female connector, wired as listed in Table A-3. Table A-3. RS-530 Interface Adapter Cable DB-15 Interface Connector Pin DB-25 Connector Pin (User’s Side) Designation 1 1 2 A-4 Direction Function LINK DATA AA – – Frame ground (shield) 2 BA(A) OUT IN TX data - A wire 3 4 CA(A) OUT N.
MAIN LINK AND DATA CHANNEL INTERFACES V.35 Interface Adapter Cable The V.35 interface adapter cable, CBL-DV-MUX/V.35, is terminated on the user side in a 34-pin female connector, wired as listed in Table A-4. Table A-4. V.35 Interface Adapter Cable DB-15 Interface Connector Pin DB-34 Connector Pin (User’s Side) ITU-T Rec. V.35 Circuit LINK DATA 1 A 101 – – Frame ground (shield) 2 P 103 OUT IN TX data - A wire 3 C 105 OUT N.
APPENDIX A - CONNECTION DATA V.24/RS-232 Interface Adapter Cable The V.24/RS-232 interface adapter cable, CBL-DV-MUX/232/N, is terminated on the user side in a 25-pin D-type female connector, wired as listed in Table A-5. Table A-5. V.24 Interface Adapter Cable 15-Pin Connector 25-Pin Connector Line Designation 112 1 1 103 2 105 V.
VOICE CHANNEL INTERFACE A-3. VOICE CHANNEL INTERFACE The voice channel interface has 8-pin RJ-45 connectors, wired as listed in Tables A-6 and A-7. Table A-6. FXO and FXS Voice Channel Interfaces, Connector Wiring Pin Designation Function 1, 2, 3 – 4 RING 2W voice input/output 5 TIP 2W voice input/output 6, 7, 8 – Not connected Not connected Table A-7.
APPENDIX A - CONNECTION DATA A-4. DC POWER CONNECTOR The DC power connector is a three-pin circular connector, wired in accordance with Table A-8. Pin locations are also identified. Table A-8.
APPENDIX B. DV-MUX3 WITH MIX OPTION Contents General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interchange of Interface Boards . . . . . . . . . . . . . . . . . . . . Page B-1 B-2 B-1. GENERAL Among other configurations, DV-MUX3 units can be operated in back-to-back configurations (figure B-1). For such applications, each DV-MUX3 must include one FXO interface and one FXS interface (this configuration is ordered under the MIX option).
APPENDIX B - DV-MUX WITH MIX OPTION B-2. INTERCHANGE OF INTERFACE BOARDS WARNING Interface Board Interchange • • • • • Before carrying out the following procedure, read carefully the WARNING and CAUTION appearing on page 2-3 of this manual. Open DV-MUX3 case in accordance with the instructions appearing in the Opening DV-MUX3 Case section in para. 2-4. Refer to figure B-2 and identify the interface boards. Release the screws fastening the two boards. Remove the boards and interchange their positions.
APPENDIX C. RACK INSTALLATION Contents Page General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation of Single DV-MUX3 Unit . . . . . . . . . . . . . . . . . . Installation of Two DV-MUX3 Units . . . . . . . . . . . . . . . . . . C-1 C-2 C-3 C-1. GENERAL The DV-MUX3 can be installed in 19" racks. Unit height corresponds to 1U (1.75"), and the width is slightly less than half of the available mounting width.
APPENDIX C - RACK INSTALLATION C-2. INSTALLATION OF SINGLE DV-MUX3 UNIT The rack adapter kit includes one short bracket and one long bracket. The brackets are fastened by means of screws to the two side walls of the case, as shown in figure C-1. Figure C-1. Installation of Single DV-MUX3 Unit in 19" Rack To prepare the unit for rack installation: C-2 • Attach the two brackets to the side walls of the unit.
INSTALLATION OF TWO DV-MUX3 UNITS C-3. INSTALLATION OF TWO DV-MUX3 UNITS General The rack adapter kit includes two rails for attaching the two units side by side, two short adapter brackets, and various hardware.
APPENDIX C - RACK INSTALLATION Figure C-2. Preparation of Two DV-MUX3 Units for Installation in 19" Rack • • • • • Fastening the Two Units Fasten one short adapter bracket to the left-hand side wall of the unit intended to be on the left. Use two of the four longer screws supplied in the kit, and insert flat washers. Use the same procedure to fasten the second short adapter to the right-hand wall of the unit intended to be on the right.
24 Raoul Wallenberg St., Tel Aviv 69719, Israel Tel: +972-3-6458181, Fax: +972-3-6483331, +972-3-6498250 E-mail: erika_y@rad.co.il, Web site: http://www.rad.com Customer Response Form RAD Data Communications would like your help in improving its product documentation. Please complete and return this form by mail or by fax or send us an e-mail with your comments.
Error Report Type of Error(s) ❒ Incompatibility with product or Problem(s): ❒ Difficulty in understanding text ❒ Regulatory information (Safety, Compliance, Warnings, etc.) ❒ Difficulty in finding needed information ❒ Missing information ❒ Illogical flow of information ❒ Style (spelling, grammar, references, etc.) ❒ Appearance ❒ Other _________ Please list the exact page numbers with the error(s), detail the errors you found (information missing, unclear or inadequately explained, etc.