Instruction manual

CHAPTER 4.
DIAGNOSTICS
Contents Page
General ................................ 4-1
Description of Diagnostic Functions .................. 4-2
Troubleshooting Instructions ..................... 4-5
4-1. GENERAL
Three types of diagnostic functions are available:
Remote loopback.
BERT testing (available only on the data channel).
Tone injection (available only on the voice channels).
The BERT, tone injection, and remote loop are initiated from the front panel PATT
and RLB push-buttons, respectively, on the channel selected by means of the SE-
LECT switch.The operating procedures are explained in para. 3-3.For a functional
description of the test functions available on each channel, refer to para. 4-2.
The activation of the tests can be disabled by an internal switch, located on the DV-
MUX3 main board (figure 2-2). If troubleshooting is required and the DV-MUX3
does not respond to the PATT and RLB push-buttons,first check the position of the
switch.
When performing tests, observe the following guidelines and restrictions:
Activation of a channel test or loop interrupts the service to the users served
by the DV-MUX3 channel under test.
Activation of the main link loop interrupts the service to all the users served
by the DV-MUX3 link.
On any channel, only one DV-MUX3 can activate a remote loopback. If the
remote loopback has already been activated by the other DV-MUX3, the
TEST indicator starts flashing (indication of configuration error).
DV-MUX3 Installation and Operation Manual 4-1