System information
Access Controller xl Module for the Series 5300xl Switches
BIOS POST Event Log Messages
BIOS POST Event Log Messages
If a critical BIOS power on self test (POST) failure occurs when the ACM is
inserted into a slot in a 5300xl chassis, the message below is posted to the
Event Log. The 5300xl switch resets the ACM, up to two times (a total of three
attempts to pass the POST). If the ACM fails three consecutive times, the
module does not power on. The 5300xl switch can operate successfully if this
occurs.
Slot <slot-id> Access Control Module Bios POST tests
failed, Post bitmap = 0xXXXX
The POST error bitmap values are explained below.
0x0001
IDE failure.
0x0002
System memory failure.
0x0004
Shadow memory failure.
0x0020
Protected memory failure.
0x0040
CMOS not ready error.
0x0100 Periodic timer failure.
0x0800 Device configuration error.
0x1000 Memory configuration error.
0x2000 Non-volatile RAM failure.
0x4000 External or CPU cache failure.
0x8000 Level2 cache failure.
12-32