User Guide
RTX8200 LOCATION GATEWAY GUIDE 4.6 12 | P a g e
Proprietary and Confidential
Position 1 - Gateway Settings
In this example, the beamforming will be configured to steer left into the door opening and the attenuation is set to -
30 dB for detection only in the door.
Position 2 - Gateway Settings
In this example, the beamforming will be configured the center setting and the attenuation is set to -16 dB for reliable
detection after tracked object has walked through the door. In this case the object needs to travel a meter inside the
room.
Table of settings:
SETTING
POSITION 1
POSITION 2
POSITION 3
ANTENNA ARRAY
Left
Center
Center
ATTENUATION
-30 dB
-16 dB
-16 dB
EFFECTIVE RANGE
Less than a meter
2-3 meters
2-3 meters
Use case: Room installation:
If the user wants to detect presence in a small room or office RTX
recommends installing this in the top corner of a room. The power
level should be adjusted according to the size of the room. We have
provided a table with different room sizes and power settings. The
Antenna direction should be set to “center” in all the cases. This is
with the beacon in TX mode. The values given is measured inside a
fully equipped office space, it is very likely that the user will have to
tweak the values to fit their exact needs.
Table of settings
Antenna Array
Center
Center
Center
Center
Center
Center
Attenuation
0 dB
8 dB
16 dB
30 dB
38 dB
46 dB