Installation Guide
Table Of Contents
- Contents
- 1 About this Installation Guide
- 2 Planning the SC8800-S AP Installation
- 3 Preparing the SC8800-S AP at the Depot and Shipping to the Field
- 4 Installing the SC8800-S AP in the Field
- Installation Components and Constraints
- Deploying the Access Point
- Mounting the Access Point
- Mounting the U-Joint Bracket to the Main Mounting Bracket
- Attaching the Main Mounting Bracket to a Flat Surface
- Attaching the Main Mounting Bracket to a Wooden Pole
- Attaching the Main Mounting Bracket to a Metal Pole
- Mounting the Hook Bracket to the U-Joint Bracket
- Assembling the AP Attachment Bracket and the Access Point
- Attaching the AP Attachment Bracket and AP to the Hook Bracket
- Safety-Cabling the AP
- Mounting External Antennas (Optional)
- Verifying Access Point Operation
- 5 What to Do Next
- Appendix A: Ruckus Wireless-Supplied and Customer-Ordered Parts
- Appendix B: Resetting the Access Point to Factory Default Settings
- Appendix C: Installer Mounting Dimensions
44
Installing the SC8800-S AP in the Field
Mounting the Access Point
Assembling the AP Attachment Bracket and the Access
Point
1. Place the AP attachment bracket onto the back side of the AP so that the four screw
holes on the bracket align with the four screw holes on the AP. Make sure that the
longer end of the AP attachment bracket is on the same side as the AP antenna
connectors. See Figure 26
.
Figure 26. Attaching the AP Attachment Bracket to the AP
2. Use four small M6 bolt and washer sets to mount the AP attachment bracket to the AP.
Tighten the bolts to 9.5 N.m (7 ft-lbs).
3. Continue with “Attaching the AP Attachment Bracket and AP to the Hook Bracket”
on
page 45.