Step-by-step Instructions
Table Of Contents
FIGURE 8 Horizontal mounting with Long Linkage Arm
1. Loosely assemble the linkage bracket (A), the U-joint bracket
(C), one serrated e
xternal-tooth lock washer (B), and one M8
bolt and washer set (D).
FIGURE 9 Attaching the Llnkage Bracket to the U-joint
Bracket
FIGURE 10 Additional Orientation view of the
attachment of Linkage Br
acket to U-joint Bracket
2. Set the azimuth required by the AP.
3. Tighten the M8 bolt to 13.6 N-m (10 ft-lbs.)
4.
Continue with Step 5: Attaching the AP Bracket to the
Linkage Bracket on page 3.
Step 5: Attaching the AP Bracket to the
Linkage Bracket
Attach the AP bracket to the linkage bracket using the included
bolt, nut, lock washer, at washer, serrated external-tooth
washer shown in Figure 10.
The AP bracket attaches to the linkage bracket using an M8 bolt
and washer set. The linkage bracket is symmetrical, and either
end can be attached to the AP bracket.
NOTE: Make sur
e that linkage bracket is installed with its
serrated external-tooth lock washer on the inside of the AP
bracket anges. This ensures that the elevation adjustment
does not change.
As described in Step 4: Mounting the Linkage Brack
et to the
U-Joint Bracket on page 2, loosely assemble the AP bracket
(shown in Figure 10), the linkage bracket (A in Figure 9), the
second serrated external-tooth lock washer (B in Figure 9),
and the second M8 bolt and washer set (D in Figure 9).
Step 6: Attaching the AP Bracket to the
Access Point
1. Place the AP bracket on to the back side of the AP so that the
four larger screw holes on the bracket align with the four
screw holes on the AP. Make sure that the end of the AP
bracket with the hoisting loop is on the same side as the AP
PoE IN port.
FIGURE 11 Attaching the AP brack
et to the AP
2. Use four 0.5-inch x 0.250-28 hex bolts with split lock and at
washer sets to mount the AP brack
et to the AP. Tighten the
bolts to 2.5-3.0 N.m or 22-27 in-lbs.
CAUTION! Make sur
e that the screws are no longer than
0.5 inch. If a screw is longer than 0.5 inch, it can damage
the AP chassis.
3. If required, suspend the AP by attaching a carabiner to the
hoisting loop on the AP brack
et.
NOTE: This kit may include extr
a screws, nuts, and
washers. You may use the extras wherever required.
4. Continue with Step 7: Setting the Elevation and Tightening
the Ele
vation Bolt on page 3.
Step 7: Setting the Elevation and Tightening
the Elevation Bolt
1. Set the elevation required by the AP.
2. Tighten the M8 bolt to13.6 N-m (10 ft-lbs.)
3. Continue with Step 8: Earth Grounding the AP on page 4.
Copyright
©
2018 ARRIS Enterprises LLC. All rights r
eserved. Page 3 of 4
Published December 2018, Part Number 800-71412-001 Rev B