SDS

Conforms to OSHA HazCom 2012 & CPR Standards
SAFETY DATA SHEET
Trade Name: RUG DOCTOR Hi-Traffic Pretreatment Print date: 2014-02-27
Page 3 of 9
5.3 SPECIAL HAZARDS ARISING FROM THE CHEMICAL
Products of Combustion:
May include, and are not limited to: oxides of carbon.
Explosion Data:
Sensitivity to Mechanical Impact:
Not available.
Sensitivity to Static Discharge:
Not available.
5.4 SPECIAL PROTECTIVE EQUIPMENT AND PRECAUTIONS FOR FIRE FIGHTERS
Keep upwind of fire. Wear full fire fighting turn-out gear (full Bunker gear) and respiratory protection
(SCBA).
Section 6: ACCIDENTAL RELEASE MEASURES
6.1 PERSONAL PRECAUTIONS, PROTECTIVE EQUIPMENT AND EMERGENCY PROCEDURES
Use personal protection recommended in Section 8. Isolate the hazard area and deny entry to
unnecessary and unprotected personnel.
6.2 METHODS AND MATERIALS FOR CONTAINMENT AND CLEANING - UP
Methods for Containment:
Contain and/or absorb spill with inert material, then place in a
suitable container. Do not flush to sewer or allow to enter waterways.
Use appropriate Personal Protective Equipment (PPE).
Methods for Clean
ing
-
Up:
Scoop up material and place in a disposal container.
Section 7: HANDLING AND STORAGE
7.1 PRECAUTIONS FOR SAFE HANDLING
H
andling:
Avoid contact with skin and eyes. Do not swallow. Avoid breathing
dust/fume/gas/mist/vapors/spray. Handle and open container with
care. When using do not eat, drink or smoke. (See section 8)
General Hygiene Advice:
Launder contaminated clothing before reuse. Wash hands before
eating, drinking, or smoking.
7.2 CONDITIONS FOR SAFE STORAGE, INCLUDING ANY INCOMPATIBILITIES
Storage:
Keep out of the reach of children. Keep container tightly closed. (See
section 10)
Section 8: EXPOSURE CONTROLS/PERSONAL PROTECTION
8.1 CONTROL PARAMETERS
Exposure Guidelines
Occupational Exposure Limits
Ingredient
OSHA
-
PEL
ACGIH
-
TLV
Trisodium hydrogendicarbonate Not available. Not available.
Ethoxylated alcohol Not available. Not available.
8.2 EXPOSURE CONTROLS
Engineering Controls:
Use ventilation adequate to keep exposures (airborne levels of dust,
fume, vapor, etc.) below recommended exposure limits.