User guide

Technical Specifications
37
RuggedCom
®
RuggedServer RS416 Family Installation Guide rev118
6.3 Data Port Specifications
6.3.1 Serial Ports
6.3.1.1 Copper Ports
Parameter Specifications Notes
Baud Rate
300 bps – 230
kbps
Connector DB9 or RJ45
Isolation 2.5 kV
RMS 1-minute
Table 16: Copper Port Specification
6.3.1.2 Fiber Optic Ports
Parameter Specifications
Mode Multimode
Connector ST
Typical Dist. (km) 5
Optical Wavelength
(nm)
820
Cable Size
Core/Cladding (um)
50/125
62.5/125
Table 17: Fiber Optic Port Specification
NOTES:
1. Maximum segment length is greatly dependent on factors such as fiber quality,
and number of patches and splices. Please consult RuggedCom sales
associates when determining maximum segment distances.
6.3.2 IRIG-B Ports
Parameter Typical Value
Input Voltage TTL-Compatible
Input Impedance > 200 kΩ
Table 18: IRIG-B PWM Input
Parameter Typical Value
Output Current (I
S
) 100 mA
Output Voltage (V
S
) 5 V
p-p
Output Impedance (R
S
) 50 Ω
Table 19: IRIG-B Port Output Specifications