6.3.3 Ethernet Ports
6.3.3.1 Copper Ports
Parameter Specification Notes
Speed 10/100 Mbps Auto-negotiating
Duplex FDX / HDX Auto-negotiating
Cable-Type > Category 5 Shielded/Unshielded
Wiring Standard TIA/EIA T568A/B Auto-Crossover, Auto-polarity
Max Distance 100 m
Connector RJ45
Isolation 1.5 kV RMS 1-minute
PoE Voltage 44-57 V
PoE Current 350 mA
Table 20: Ethernet Ports - Copper Specifications
6.3.3.2 Fiber Optic Ports
The following sections detail fiber optic specifications on ports that can be ordered with
the RS416. The user determines the type of optics at time of ordering and can determine
the modules installed on a particular unit by reading the factory data file via the ROS
TM
user interface. The following section provides detailed specifications of fiber optic
modules.
The dual-port fast Ethernet optical specifications for slots 5 and 6 are shown in Error!
Reference source not found. organized by module order code. Module order codes
are contained within each product’s factory data when assembled and configured at the
factory. Consult ROS
TM
to determine the optical assemblies installed in a particular
product.
Optics
Order Code
Speed
Standard
Mode /
Connector
Tx
(nm)
Cable
Type
(um)
Tx
min
(dBm)
Tx
max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Typical
Distance
(km)
Power
Budget
(dB)
12-11-0011 10FL MM/ST 820 62.5/125 -16 -9 -34 -11.2 2 18
50/125 -19.8 -12.8 -34 -11.2 2 14.2
12-11-0012 10FL SM/ST 1310 9/125 -27 -14 -35 -3 5 8
12-11-0007 100FX MM/ST 1300 62.5/125 -19 -14 -33.9 -14 2 14.9
50/125 -22.5 -14 -33.9 -14 2 11.4
12-11-0009 100FX MM/SC 1300 50/125 -22.5 -14 -33.9 -14 2 11.4
62.5/125 -19 -14 -33.9 -14 2 14.9
12-11-0008 100FX MM/MTRJ 1300 50/125 -22.5 -14 -33.5 -14 2 11
62.5/125 -19 -14 -33.5 -14 2 14.5
12-11-0046 100FX MM/LC 1310 62.5/125 -19 -14 -32 -14 2 13