12-11-0006 100FX SM/ST 1310 9/125 -15 -7 -34 -3 20 19
12-11-0005 100FX SM/SC 1300 9/125 -15 -8 -31 -7 20 16
12-11-0004 100FX SM/LC 1300 9/125 -15 -8 -38 -3 20 23
12-11-0031 100FX SM/SC 1310 9/125 -5 0 -34 -3 50 29
12-11-0032 100FX SM/LC 1310 9/125 -5 0 -35 -3 50 30
12-11-0033 100FX SM/SC 1310 9/125 0 5 -37 0 90 42
12-11-0034 100FX SM/LC 1310 9/125 0 5 -37 0 90 37
Table 21: Ethernet Ports – Fiber Optic Specifications
NOTES:
Maximum segment length is greatly dependent on factors such as fiber quality, and
number of patches and splices. Please consult RuggedCom sales associates when
determining maximum segment distances.
1. All optical power numbers are listed as dBm averages.
2. All cabling is duplex type unless otherwise specified.
3. These transceivers utilize a distributed feedback (DFB) type laser and are rated
for -20C to +85C operation only.
6.4 Operating Environment
Parameter Range Comments
Ambient Operating
Temperature
-40 to 85C
Ambient Temperature
as measured from a
30cm radius
surrounding the center
of the RS1600
enclosure.
Ambient Relative Humidity 5% to 95% Non-condensing
Ambient Storage
Temperature
-40 to 85C
Table 22: Operating Environment