RuggedSwitch™ RS900GP Hardware Installation Guide Revision 100 - November 10, 2011 www.RuggedCom.
RuggedSwitch™ RS900GP RuggedSwitch™ RS900GP: Hardware Installation Guide Copyright © 2011 RuggedCom Inc. All Rights Reserved Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights are reserved, particularly for the purposes of patent application or trademark registration. This document contains proprietary information, which is protected by copyright.
RuggedSwitch™ RS900GP Table of Contents FCC Statement And Cautions ................................................................................................... 6 1. Product Overview ................................................................................................................... 7 1.1. RS900GP Front Panel ................................................................................................ 9 2. Installation ................................................................
RuggedSwitch™ RS900GP List of Figures 1.1. 2.1. 2.2. 2.3. 2.4. 2.5. 2.6. 2.7. 2.8. 2.9. 3.1. RS900GP Front Panel ........................................................................................................ 9 DIN Rail Mounting ............................................................................................................ 10 Front Panel Mounting ....................................................................................................... 11 Rear Panel Mounting ............
RuggedSwitch™ RS900GP List of Tables 1.1. Front Panel LED Definitions ............................................................................................... 9 2.1. RS232 Female DCE Pinout .............................................................................................. 15 2.2. RJ45 Ethernet Pin Assignment ......................................................................................... 16 3.1. Operating Environment ..............................................................
FCC Statement And Cautions FCC Statement And Cautions Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
1. Product Overview 1. Product Overview The RuggedSwitch™ RS900GP is an industrially hardened, fully managed Ethernet switch providing dual fiber optical Gigabit Ethernet ports and eight Fast Ethernet copper ports - each capable of supplying high power 802.3at compliant power over Ethernet.
1. Product Overview Power Supply • 2 (redundant) 54VDC inputs (51-57VDC) • Supports 8 30W PoE powered devices (minimum 260W total output) • Supports power supply sharing • Reverse polarity protection • CSA/UL 60950 safety approved to +85°C Simple Plug and Play Operation • Plug and play operation 802.3af/802.
1. Product Overview 1.1. RS900GP Front Panel Figure 1.1. RS900GP Front Panel LED Indicator LED Color and State Power LED Green, steady. Alarm LED Red, steady. Description Power is on. Alarm condition exists. Ethernet Port 1-8 Link LED Green, steady. Network link. Ethernet Port 1-8 Link LED Green, blinking. Network activity. Ethernet Port 1-8 PoE LED Orange, steady. PoE is enabled and powered on. Ethernet Port 1-8 PoE LED Orange, blinking. PoE is enabled and powered off.
2. Installation 2. Installation 2.1. DIN Rail Mounting An optional DIN rail mounting bracket is available for the RS900GP. Figure 2.1.
2. Installation 2.2. Panel Mounting Options The RS900GP can be equipped with front, rear, or side panel mount brackets. 2.2.1. RS900GP Front Panel Mount Option The front panel mounting brackets fit flush with the front of the RS900GP. Figure 2.2.
2. Installation 2.2.2. RS900GP Rear Panel Mount Option The rear panel mounting brackets fit flush with the rear of the RS900GP. Figure 2.3.
2. Installation 2.2.3. RS900GP Side Panel Mount Option The side panel mounting brackets fit flush with the side of the RS900GP. Figure 2.4.
2. Installation 2.3. DC Power Supply Wiring and Grounding Figure 2.5. DC Power Supply Wiring and Grounding The RS900GP low voltage DC power supply features reverse polarity protection and dual independent inputs. This feature allows the connection of two DC sources with the same nominal voltage to provide redundant power supply inputs. The DC source must be connected to the DC inputs according to the polarity markings on the unit. 1.
2. Installation 2.4. Failsafe Output Wiring and Specifications The “Failsafe” output relay is provided to signal critical error conditions that may occur on the RS900GP. The contacts are energized upon power up of the unit and remain energized until an alarm condition or power loss occurs. Figure 2.7. Failsafe Output Relay 2.5. RS232 Port Wiring The RS232 port is used for configuring the unit. A straight-through serial cable with a DB-9 connector is required.
2. Installation 2.6. RJ45 Ports: Signal Description The RS900GP has several 10/100BaseTX ports that allow connection to standard CAT-5 UTP cable with RJ45 male connectors. The RJ45 receptacles are directly connected to the chassis ground on the unit and can accept shielded CAT-5 cables. If shielded cables are used, care must be taken to ensure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end. Figure 2.9.
3. Specifications 3. Specifications 3.1. Operating Environment Parameter Ambient Operating Temperature Range Comments -40 to 85°C Ambient Temperature as measured from a 30cm radius surrounding the center of the RS900GP enclosure. Non-condensing Ambient Relative Humidity 5% to 95% Ambient Storage Temperature -40 to 85°C Operating Altitude 0 to 15240m (0 to 50000 ft) Over temperature range of -40 to 85°C Table 3.1. Operating Environment 3.2. Power Supply Specifications 3.2.1.
3. Specifications 3.4. Twisted Pair Data Port Specifications Data Port Media Distance Connector Type 10/100 Mbps Cat 5 UTP or STP 100m RJ45 Table 3.6.
3. Specifications 3.5. Fiber Optic Port Specifications For maximum flexibility, RuggedCom Inc. offers a number of different transceiver choices for Gigabit fiber optic communications. The following table details fiber optic specifications based on the order code/transceiver selected at time of ordering. Mode / Connector Tx λ (nm) Cable a Type 1. 2LCMM MM / LC 850 50µ/125 -9.5 / -4 -20 0 0.5 2LC10 SM / LC 1310 9µ/125 -9.
3. Specifications 3.6. Physical Dimensions Figure 3.1. RS900GP Physical Dimensions Parameter Value Comments Dimensions 6.95 × 3.63 × 6.08 inches ( 17.653 × 9.22 × 14.4432 cm) (Length × Width × Depth Weight To be determined Ingress Protection IP40 Enclosure Cast Aluminum (1mm objects) Table 3.8.
3. Specifications 3.7. Type Test Specifications 3.7.1. IEC 61850-3 Type Tests Test Test Levels Severity Levels Enclosure Contact +/- 8kV 4 Description IEC 61000-4-2 ESD Enclosure Air +/- 15kV 4 IEC 61000-4-3 Radiated RFI Enclosure ports 20 V/m x Signal ports +/- 2kV @ 2.5kHz x IEC 61000-4-4 Burst (Fast Transient) D.C. Power ports +/- 2kV 4 Earth ground ports +/- 2kV 4 Signal ports +/- 2kV line-to-earth, +/- 1.5kV line-to-line 4 D.C. Power ports +/- 1.
3. Specifications 3.7.2. IEEE 1613 Type Tests IEEE Test IEEE 1613 Clause Description C37.90.3 9 ESD C37.90.2 8 Radiated RFI C37.90.1 7 C37.90.1 Fast Transient 7 C37.90 +/- 8kV Enclosure Air +/- 12kV Enclosure ports 35 V/m Signal ports +/- 2kV @ 2.5kHz D.C. Power ports +/- 2kV Earth ground ports +/- 2kV Signal ports 2.2kV common mode @ 1MHz D.C. Power ports 2.2kV common & differential mode @ 1MHz Signal ports 5 kV (Failsafe Relay) D.C.
3. Specifications 3.8. Agency Approvals Agency Standards Comments CSA CSA C22.2 No. 60950, UL 60950 Approved CE EN 60950, EN 61000-6-2 CE Compliance is claimed via Declaration of Self Conformity Route FCC Part 15, Class A Approved EN55022, Class A Approved FDA/CDRH 21 CFR Chapter 1, Subchapter J Approved IEC/EN EN60825-1:1994 + A11:1996 + A2:2001 Approved CSA Hazardous Locations Class 1, Division 2, Groups A, B, C,& D.
Appendix A. Warranty Appendix A. Warranty RuggedCom warrants this product for a period of five (5) years from the date of purchase. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. For warranty details, visit www.RuggedCom.com or contact your customer service representative. Should this product require service, contact the factory at: RuggedCom Inc.