Specifications

External Control
D-113d Projection System Installation/Operation Manual 105
PRE
L
IMINAR
Y
Command and Response
Examples
Here are some examples of serial commands and their responses:
Serial Command ListTable 6-1 lists all supported commands.
Command Command Data Response
Power query when
unit is powered on
(PWR?) [CR] (0;PWR=1) [CR]
Set power to 0 (off)
(PWR=0) [CR] (0;PWR=0) [CR]
Increment bright-
ness from 24 to 25
(BRT+) [CR] (0;BRT=25) [CR]
Invalid command
(ZZZ=0) [CR] (1;ZZZ=0) [CR]
Invalid parameter
(received string,
expected integer)
(CON=”Some string”)
[CR]
(9;CON=”Some string”)
[CR]
Table 6-1. Serial Commands
Setting
Command
Code
Read/
Write
Inc/
Dec
Min
Value
Max
Value
String? Notes
Advanced Color Temp Auto Color
Enable
AAC R/W No 0 1 No 0 = Off; 1 = On
Advanced Color Temp Diagnostic
Color
AAD R/WNo06No0 = White
1 = Red
2 = Green
3 = Blue
4 = Yellow
5 = Cyan
6 = Magenta
PCE Blue x ABX R/W Yes -100 100 No
PCE Blue y ABY R/W Yes -100 100 No
Adjustment Mode ADJ R/W No 0 2 No 0 = Both
1 = Left
2 = Right
PCE Green x AGX R/W Yes -100 100 No
PCE Green y AGY R/W Yes -100 100 No
Apply Image Alignment Values AIA R/W No 0 1 No 0 = Off; 1 = On
Advanced Color Temp Mode
Enable
AME R/W No 0 1 No 0 = Off; 1 = On
Auto New Firmware Check ANF R/W No 0 1 No 0 = Off; 1 = On
Auto Power Off Enable APE R/W No 0 1 No 0 = Off; 1 = On
Auto Power Off Timer APT R/W Yes 1 24 No
Auto Perform Upgrade APU R/W No 0 1 No 0 = Off; 1 = On