Specifications

Maintenance and Troubleshooting
D-73d Series Installation/Operation Manual 101
The “right-eye” optical engine
does not turn on or respond
to user commands. The vac-
uum fluorescent display on
the Dimension Digital Control-
ler front panel displays the fol-
lowing message:
Secondary Display Error
Communication Failure
The serial connection from
the Dimension Digital
Controller to the “right-eye”
optical engine on the
display is incorrect or the
cable is faulty.
Ensure that the
Sec. Display Control
(RS-232) output from the
Dimension Digital
Controller is properly
connected to the display
(see Figure 3-14).
The display and Dimension
Digital Controller both turn on,
but there is no picture and
on-screen menus do not
appear.
Faulty or incorrect video
connection from the
Dimension Digital
Controller to the display.
Ensure that the HDMI
output from the Dimension
Digital Controller is
properly connected to the
display (see Figure 3-14).
Try a known-good and/or
shorter HDMI cable.
The display is on and menus
appear, but there is no
picture.
Incorrect source selection.
Source component is not
turned on.
Source component is
connected incorrectly or
not at all.
Select the correct source.
Turn on the source
component.
Check connections from
the source component to
the Dimension Digital
Controller.
Image is too bright and/or
lacks definition in the bright
areas of the image.
Contrast is set too high. Lower the contrast setting.
Image appears “washed out”
and/or dark areas appear too
bright.
Brightness is set too high. Lower the brightness
setting.
Colors in the image are
swapped; for example, reds
appear blue or vice versa.
The Red/Pr, Green/Y or
Blue/Pb outputs from the
source are connected to
the wrong inputs on the
Dimension Digital
Controller.
Ensure that the source
outputs are connected to
the correct Dimension
Digital Controller input.
RGB-HD or Component HD
images appear “noisy” or
drop out intermittently.
Tracking and Phase
settings need adjustment.
The Dimension Digital
Controller is having
difficulty detecting sync
pulses from the source.
Adjust Tracking and Phase
settings (refer to Input
Position on page 76).
Adjust the Sync Threshold
setting (refer to Sync
Threshold on page 95).
Computer images do not dis-
play correctly.
The resolution and
frequency of the video
card in the computer are
not compatible with the
D-73d.
Select a compatible
resolution and vertical
frequency (refer to
Supported Timings on
page 130).
Table 5-1. Troubleshooting Chart (continued)
Symptom Possible Cause(s) Solution