O W N E R ’S O P E R A T I N G M A N U A L TM PL-50XA PL-61DHD Flat Panel Plasma Display Monitor with and Digital High Definition Controller with Vivix II Technology TM TM
THREE YEAR LIMITED WARRANTY For Plasma Displays Congratulations on your purchase of a Runco video product and welcome to the Runco family! We believe Runco produces “The World’s Finest Home Theater Products.” With proper installation, setup and care, you should enjoy many years of unparalleled video performance. This is a LIMITED WARRANTY as defined in the Magnuson-Moss Warranty Act. Please read it carefully and retain it with your other important documents.
CAUTION: THIS LIMITED WARRANTY ONLY COVERS RUNCO PRODUCTS PURCHASED FROM RUNCO AUTHORIZED DEALERS. ALL OTHER PRODUCTS ARE SPECIFICALLY EXCLUDED FROM COVERAGE UNDER THIS LIMITED WARRANTY. MOREOVER, DAMAGE RESULTING DIRECTLY OR INDIRECTLY FROM IMPROPER INSTALLATION OR SETUP IS SPECIFICALLY EXCLUDED FROM COVERAGE UNDER THIS LIMITED WARRANTY. RIGHTS, LIMITS AND EXCLUSIONS: EL IM IN A R Y Runco limits its obligations under any implied warranties under state laws to a period not to exceed the warranty period.
ADDITIONAL INFORMATION: To locate the name and address of the nearest Runco Authorized Service Center, or for additional information about this Limited Warranty, please call or write: EL IM IN A R Y RUNCO INTERNATIONAL, INC.
Safety Precautions Thank you for your purchase of this quality Runco product! It has been designed to provide you with the quality of video that is expected in a home theater. This manual is your guide through the menus and operation. For the best performance, please read it carefully and keep it handy for future reference.
1 Table of Contents THREE YEAR LIMITED WARRANTY ............................................................................. iii Safety Precautions ......................................................................................................... vi 1. Introduction ...............................................................................................................1 About This Manual .......................................................................................................
Table of Contents Connections to the PlasmaWall and DHD Controller ...................................................20 Connecting the PlasmaWall to the DHD Controller ................................................20 Connecting Source Components to the DHD Controller .......................................22 RS-232 Controller Connection ..............................................................................26 Connecting 12-Volt Trigger Outputs to External Theater Components ..................
1 List of Figures 2-1. PlasmaWall Controls and Indicators .............................................................................5 2-2. PlasmaWall Connectors ...............................................................................................6 2-3. DHD Controller Front Panel ..........................................................................................8 2-4. DHD Controller Rear Panel .........................................................................................
PR EL IM IN A R Y List of Figures x Runco PlasmaWall Owner’s Operating Manual
1. Introduction Y This Owner’s Manual describes how to install, set up and operate the Runco PlasmaWall Flat-Panel Plasma Display Monitor and DHD Controller (Models PL-50XA and PL-61DHD). Throughout this manual, the Runco PlasmaWall Flat-Panel Plasma Display Monitor is referred to simply as the “PlasmaWall.” EL IM IN A R Runco has prepared this manual to help home theater installers and end users get the most out of the PlasmaWall. 1.
Introduction Graphic Conventions: These symbols appear in numerous places throughout the manual, to emphasize points that you must keep in mind to avoid problems with your equipment or injury: Note NOTES emphasize text with unusual importance or special significance. They also provide supplemental information. Caution CAUTIONS alert users that a given action or omitted action can degrade performance or cause a malfunction.
Introduction The PlasmaWall™ is large enough to be used as the centerpiece of any home theater, yet slim enough (less than five inches) to be used in any type of room environment. Its size is only one of its advantages. It also has HDTV resolution of 1365 x 768, is bright enough to be used in any lighting situation, and can be mounted on a wall or placed on a tabletop. 1.
Introduction Parts List ➤ Your PlasmaWall is shipped with the following items. If any items are missing or damaged, please contact your Runco dealer or Runco Customer Service at (800) 23-RUNCO.
2. Controls and Functions PR EL IM IN A R Y Figure 2-1 and Figure 2-2 show the locations of the PlasmaWall controls, indicators and connectors. Located on bottom of Plasma MENU / ENTER 7 VOLUME DOWN UP 6 LEFT/- RIGHT/+ Located on bottom of Plasma INPUT SELECT /EXIT 5 4 1 3 Figure 2-1. PlasmaWall Controls and Indicators 1. POWER BUTTON Turns the monitor’s power on and off. 2. REMOTE CONTROL SENSOR Receives the signals from the remote control. 3.
Controls and Functions 4. INPUT SELECT/EXIT Not used with this model. Use the DHD Controller to select an input source. 5. LEFT/– and RIGHT/+ Not used with this model. 6. VOLUME DOWN and UP Not used with this model. 7. MENU/ENTER Not used with this model. Use the DHD Controller to access the on-screen menus. The Power on/off switch does not disconnect the plasma display completely from the supply mains.
Controls and Functions 1. POWER INPUT (100 to 240 VAC) Connect the PlasmaWall to power here, using the included power cord. 2. EXTERNAL SPEAKER OUTPUTS Not used. Connect speakers to an external audio amplifier/receiver. 3. VIDEO1, 2 (RCA, S-Video) Not used. Connect all video sources to the DHD Controller. 5. DVD/HD1 DVD/HD2 Not used. Connect all video sources to the DHD Controller. EL IM IN A R 6. PC/RGB (15-pin D-Sub) Connect the RGBHV (5xBNC) output from the DHD Controller here. Y 4.
Controls and Functions 2.2 DHD Controller Front Panel 1 2 EL IM IN A R Y Figure 2-3 shows the controls and indicators on the DHD Controller front panel; the paragraphs that follow describe them. 3 4 5 6 7 8 9 10 Figure 2-3. DHD Controller Front Panel 1. RUNCO ICON Lights red to indicate that the DHD Controller is in standby mode; lights blue to indicate that the unit is on. PR 2. POWER BUTTON Press once to toggle from standby mode to on mode. Press it again to return to standby mode.
Controls and Functions 5. UP BUTTON Use to direct-select aspect ratios or move the menu cursor up in the On-Screen Display. When no menus are present on-screen, the UP button toggles you through aspect ratios in the following order: Anamorphic - Standard (4:3) - Letterbox - VirtualWide - Cinema (For more information about aspect ratios, refer to Table 4-1.) Y 6. LEFT BUTTON Used to direct select inputs or move the menu cursor left in the On Screen Display.
Controls and Functions 2.3 DHD Controller Rear Panel Figure 2-4 shows the rear connector panel on the DHD Controller. 4 8 10 SYSTEM CONTROL INTERFACE R/Pr G/Y B/Pb RISK OF ELECTRIC SHOCK DO NOT OPEN H V 2 OUTPUTS HD2 B/Pb Video Processor / Controller G/Y B/Pb H V EL IM IN A R R/Pr SDI V 1 SHOCK, DO NOT REMOVE COVER. NO USERSERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE CENTER.
Controls and Functions 6. COMPOSITE VIDEO INPUT Standard composite video input for connecting a VCR, camcorder, laser disc player or other composite video source. 7. S-VIDEO 1 / S-VIDEO 2 Two, standard S-Video inputs for connecting a DVD player, satellite receiver or Super VHS (S-VHS) VCR. 8. 12-VOLT (800 mA) TRIGGER OUTPUTS Connection for up to three (3), 12-volt trigger-controlled devices. 9. RS-232 OUTPUT (6-Wire, RJ-11 jack) Connect this to the EXTERNAL CONTROL input of the PlasmaWall.
Controls and Functions 2.4 DHD Controller Remote Control Figure 2-5 shows the DHD Controller remote control, and the paragraphs that follow describe its functionality. 2 Y 1 3 EL IM IN A R 4 5 6 8 7 10 11 9 PR 12 (not available on some models) 13 Figure 2-5.
Controls and Functions 1. IR OUTPUT INDICATOR Lights when a button is pressed to indicate that an IR signal is being transmitted. 2. ON / OFF Press to turn the PlasmaWall on or off. 3. ENTER Press to select a highlighted menu item or confirm a changed setting. 4. Cursor Keys ( , , , ) Use these buttons to select items or settings, adjust settings or switch display patterns.
Controls and Functions 9. Aspect Ratio Selection Buttons Use the red buttons to select an aspect ratio directly or to enter numeric characters, as follows: ANA (Anamorphic) (3) For viewing 16:9 DVDs or HDTV programs in their native aspect ratio. 4X3 (Standard 4:3) (6) Scales the input signal to fit 4:3 display mode in the center of the screen. Y LETBOX (Letterbox) (9) For viewing LaserDisc movies or non-anamorphic DVDs on a 4:3 screen.
3. Installation 3.1 Remote Control To install batteries in the remote control: EL IM IN A R Y 1. Press down the tab on the cover and pull the cover in the direction of the arrow. 2. Insert the included batteries. Ensure that the polarities correctly match the and markings inside the battery compartment. 3. Insert the lower tab of the cover into the opening, and press down the cover until it clicks in place. • When installing batteries, make sure that the battery polarities are correct.
Installation • Do not drop the remote control or expose it to moisture or high temperature. • The remote control may malfunction under a fluorescent lamp. If that occurs, move the plasma display away from the fluorescent lamp. • Make sure that there is nothing obstructing the infrared beam between the remote control and the IR receiver on the plasma display. Note The signal from the remote control can be reflected by walls or other surfaces.
Installation Table 3-1 gives a quick overview of the PlasmaWall installation process. The sections following this one provide detailed instructions. Note Installation should be performed by a qualified custom video installation specialist. For Details, refer to page... Procedure EL IM IN A R Step Y Table 3-1.
Installation 3.3 Installation Considerations Proper installation of your PlasmaWall will ensure the highest possible picture quality. Whether you are installing the PlasmaWall temporarily or permanently, you should take the following into account to ensure that it performs optimally. Mounting the PlasmaWall ➤ on a Wall or Table Stand To install the PlasmaWall, you will need either an optional table stand or wall-mounting kit. The PlasmaWall cannot be installed on its own.
Installation If you are mounting the PlasmaWall in an enclosure, leave at least 2 inches (50 mm) of space on all sides between it and surrounding objects, as shown in Figure 3-2. This allows heat to disperse, maintaining the proper operating temperature. Ventilation 50mm (2") Wall 50mm (2") EL IM IN A R Y 50mm (2") 50mm (2") Wall 50mm (2") Figure 3-2.
Installation 3.4 Connections to the PlasmaWall and DHD Controller Proceed as follows to connect the PlasmaWall to the DHD Controller, your video sources, external controller(s) -- if present -- and AC power. When connecting your equipment: • Turn off all equipment before making any connections. • Use the correct signal cables for each source. • Ensure that the cables are securely connected. Tighten the thumbscrews on connectors that have them.
Installation Digital Video Connection: The PlasmaWall has two HDMI inputs. Connect the DVI output from the DHD Controller to the DVD/HD3 input, using a DVI-to-HDMI cable. RGB-HD Connection: Connect the RGBHV output from the DHD Controller to the PC/RGB input on the PlasmaWall. Use a VGA-to-RGBHV breakout cable with 5 BNC connectors on the DHD end and a standard, 15-pin, male VGA connector on the PlasmaWall end.
Installation Connect your video sources to the DHD Controller as shown and described in the sections that follow. DVI Connections: See Figure 3-5. Use the DVI inputs whenever possible. This ensures the highest video quality because the signal is carried in the digital domain throughout the entire signal path, from source component output into the display.
Installation Digital (DTV) RGB Connections: See Figure 3-6. R/Pr G/Y INPUTS B/Pb H V TRIGGERS HD1 1 2 3 HD2 R/Pr G/Y B/Pb H V S-Video 1 Video S-Video 2 EL IM IN A R Pr Y Component Video Green Blue Horiz Vert PR Red Pb DVI 2 Y DVI 1 DTV Source Figure 3-6.
Installation Analog (Computer) RGB Connections: See Figure 3-7. 1. Refer to Computer/Video Signal Compatibility on page 55 for a list of computer signals compatible with the PlasmaWall. Use with signals other than those listed may cause some functions not to work. Note 2. Some Macintosh computers may require a Macintosh video adapter. Contact your nearest authorized service center or dealer.
Installation Composite/S-Video/Component Video Connections: See Figure 3-8. R/Pr G/Y INPUTS B/Pb H V TRIGGERS HD1 1 2 3 HD2 R/Pr G/Y B/Pb H V S-Video 1 DVI 2 Pb Y Pr Component Video Video S-Video 2 PR EL IM IN A R Y DVI 1 DVD Player, VCR, Satellite Receiver, Laser Disc etc. Figure 3-8.
Installation RS-232 Controller ➤ Connection Use a standard, 9-pin RS-232 cable to connect a PC or home theater control/automation system (if present) to the RS-232 Control port on the DHD Controller; see Figure 3-9. For more information about using this connection, refer to Serial Communications on page 47.
Installation To minimize cable clutter, use the cable clamps provided with the PlasmaWall to bundle the video, audio and control cables at the back of the display. Install the clamps as shown in Figure 3-11. Back of the unit To attach 1. 2. clamp EL IM IN A R Y mounting holes cables mounting hole PR To detach Figure 3-11.
Installation PR EL IM IN A R Y Notes: 28 Runco PlasmaWall Owner’s Operating Manual
4. Operation 1. Turn on your source components. Power cable EL IM IN A R Ferrite Core Y 2. Attach the two ferrite cores supplied with the display to each end of the AC power cable as shown in Figure 4-1. Doing so will reduce radio frequency interference (RFI) emissions to a level that conforms to FCC regulations. Use the supplied plastic bands to secure the cores in place. Ferrite Core Figure 4-1. Attaching the Ferrite Cores to the Power Cable 3.
Operation 4.2 Changing the OSD Language The PlasmaWall OSD language is initially set to English, but can also display the menus in French (Français), Spanish (Español) or German (Deutsch). To change the OSD language: 1. Press MENU and enter the Service menu passcode. 2. Press MENU again and select Service from the Main Menu. 3. Select Language from the Service Menu. 4. Press or to highlight the desired language and press ENTER. The change takes effect immediately.
Operation Note EL IM IN A R Y 5. Click the Advanced button and click the Monitor tab on the dialog box. Set the vertical frequency to 60Hz and click OK. 1. The native resolution of the PlasmaWall is 1365 x 768. Other horizontal or vertical resolutions may be scaled upward or downward to fit the display. 2. With most computers, you can get the best picture at 1024 x 768 @ 60Hz. 3.
Operation Picture Input Position ISF Presets Information (read-only) PR Test Video ISF Night - Input Image ISF Night - Input Color ISF Day - Display Color Y Aspect Ratio ISF Night - Display Color Calibration EL IM IN A R Input Source Composite S-Video 1 S-Video 2 Component SD HD/RGB 1 HD/RGB 2 DVI 1 DVI 2 HD Pass Thru 1/ HD Pass Thru 2 (available only when Display Device Input Source = RGB) Anamorphic Standard 4:3 Letterbox VirtualWide Cinema Brightness Contrast Color Tint Sharpness Left/Rig
Operation The Main Menu is the starting point for accessing all display functions. Main Menu (The Calibration and Service menus are hidden and not accessible until you enter a passcode.) Runco Video Input Source Aspect Ratio Picture Input Position ISF Presets Information Calibration EL IM IN A R From the Main Menu, select Input Source to choose a video signal source. Y Service The active source is indicated by an arrow (>) to its left; in the example at left, Composite is the active source.
Operation Table 4-1. Aspect Ratio Settings Aspect Ratio Remote Control Key Anamorphic ANA Description Select Anamorphic to view 16:9 DVDs and HDTV programs in their native aspect ratio. 4:3 images are stretched horizontally to fit a 16:9 screen. EL IM IN A R Y 16:9 Image on 16:9 Screen 4:3 Image on 16:9 Screen Standard 4:3 4X3 Standard 4:3 scales the input signal to fit in the center of the 16:9 screen.
Operation Use the controls in the Picture Menu to calibrate your PlasmaWall for optimum picture quality. The PlasmaWall has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted, industry-recognized standards for optimal video performance and has implemented a training program for technicians and installers to use these standards to obtain optimal picture quality from Runco video display devices.
Operation PLUGE patterns vary but generally consist of some combination of black, white and gray areas against a black background. The example above includes two vertical bars and four shaded boxes. Select Brightness from the Picture menu and press ENTER. Adjust the brightness so that: • The darkest black bars disappear into the background. • The dark gray areas are barely visible. • The lighter gray areas are clearly visible. • The white areas are a comfortable level of true white.
Operation EL IM IN A R Y blue red magenta green cyan yellow gray Color Saturation: On your external test pattern source, select a color bar pattern like the one shown in Figure 4-5. Figure 4-5. Typical Color Bar Pattern for Adjusting Color Saturation and Tint blue red magenta green cyan PR yellow gray Select Color and press ENTER.
Operation EL IM IN A R Y Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Picture menu and press ENTER. On your external test pattern source, select a pattern like the one shown in Figure 4-6. Adjust as needed, looking for white edges around the transitions from black to gray and differently-sized lines in the “sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate them. Figure 4-6.
Operation Overscan: Image Overscan pushes the outside edge of the active picture area of the video signal out beyond the edge of the display area. Some television programs are produced based on the assumption that older television sets may not display the outer edges of the broadcast picture area. Over scan effectively trims away these inactive, outer edges and enlarges the remaining portion of the image to fill the display area. Select from 1% to 10% of Overscan, as desired.
Operation ISF Night - Display Color: Use the Display Color settings to change the characteristics of the output signal. These settings are global (independent of any particular input). • Gain: Use the Gain controls to correct color imbalances in the bright areas of the image. A good way to do this is to use a test pattern consisting mostly of solid white areas, such as an 80 IRE “window” pattern. If the white areas contain traces of red, green or blue, decrease the Gain for that color.
Operation Splash Configure: Use the Splash Configure menu to customize the appearance of the start-up message that appears on the vacuum fluorescent display upon power-up. You can have the PlasmaWall display the owner’s name, your name, the phrase “ISF Calibrated” and/or any other string, up to 20 characters in length. Use the up or down cursor button to select a character. Use the right and left cursor buttons to change the cursor position. Press MENU when you have finished entering text.
Operation Remote Control: The Remote Control menu shows you the primary and secondary infrared (IR) codes to which the DHD Controller and PlasmaWall will respond. By default, both are set to 17. You can change these codes if either: • Another device in the theater (a DVD player, for example) is responding to commands from the PlasmaWall remote control in ways that are unpredictable or undesirable.
Operation HD Format: If for some reason the PlasmaWall does not properly detect the incoming signal format (color space) on the HD1 or HD2 inputs, specify it here (RGB or YUV). Otherwise, leave it set to Auto. Triggers: Select Triggers from the Service menu to configure the 12-volt trigger outputs. You can assign one or more trigger outputs to each aspect ratio. Those triggers are then activated by selecting that aspect ratio.
Operation PR EL IM IN A R Y Notes: 44 Runco PlasmaWall Owner’s Operating Manual
5. Maintenance and Troubleshooting Table 5-1 provides some general guidelines for troubleshooting problems you may encounter with the PlasmaWall. If you encounter an issue not described here, please contact your Runco dealer or Runco Technical Support. The display does not turn on after initial installation. Possible Cause(s) Solution EL IM IN A R Symptom Y Table 5-1. Troubleshooting Chart • The PlasmaWall is not plugged in or the AC outlet is not active. • The remote control batteries have run out.
Maintenance and Troubleshooting Table 5-1. Troubleshooting Chart (continued) Symptom Possible Cause(s) Solution • The resolution and frequency of the video card in the computer are not compatible with the PlasmaWall. • Select a compatible resolution and vertical frequency (refer to Computer/Video Signal Compatibility on page 55). The image is too large or too small. • Image size needs adjusting. • Adjust the image size (refer to Input Position on page 38).
6. Serial Communications To interface the PlasmaWall with a home theater automation/control system or a PC running terminal emulation software, connect it to the RS-232 output of the DHD Controller as shown in Figure 3-4. Connect your control system or PC to the RS-232 input of the DHD Controller as shown in Figure 3-9. 6.
Serial Communications Table 6-1. Serial Commands (continued) Parameter (min/max) Command Description NA YES Selects the RGB HD 1 input HD2 NA YES Selects the RGB HD 2 input DVI1 NA YES Selects the DVI 1 input DVI2 NA YES Selects the DVI 2 input HD1PASS NA YES Loops HD1 Input to RGB/HD output HD2PASS NA YES Loops HD2 Input to RGB/HD output OUT169 NA YES Sets the output screen to 1.
Serial Communications Table 6-1.
Serial Communications Table 6-1.
7. Specifications 7.1 PlasmaWall Specifications Table 7-1 lists the PlasmaWall specifications. Table 7-1. PlasmaWall Specifications 1365 x 768 WXGA Screen Size (diagonal): Model PL-50XA -- 50 in. Model PL-61DHD -- 61 in. Active Screen Area: Model PL-50XA -- 43.5 x 24.5 in. (1106 x 622 mm) Model PL-61DHD -- 53.2 x 29.9 in.
Specifications 7.2 DHD Controller Specifications Table 7-2 lists the DHD Controller specifications. Table 7-2.
Specifications PR EL IM IN A R Y Figure 7-1 and Figure 7-2 show the PlasmaWall dimensions (all dimensions are in inches). Figure 7-1. PlasmaWall Model PL-50XA Dimensions Runco PlasmaWall Owner’s Operating Manual 53 7.
PR EL IM IN A R Y Specifications Figure 7-2.
Specifications The PlasmaWall can display video signals from a variety of computer sources via its PC/RGB and HDMI inputs. Table 7-3 lists the signal types that are compatible with the PlasmaWall, and indicates which of those are VESA standards. Table 7-3. Computer/Video Signal Compatibility Chart Signal Type Horiz. Vert. neg 70.10 31.50 neg IBM 59.90 31.50 neg MAC 66.70 35.00 Sync on Green 72.80 37.90 neg neg 75.00 37.50 neg neg 85.00 43.30 neg neg 100.40 51.10 neg neg 120.
Specifications Table 7-3. Computer/Video Signal Compatibility Chart (continued) Signal Type Mode Vertical (Dots x Lines) Frequency (Hz) Horizontal Frequency (kHz) Sync Polarity Vert. 1280x1024 72.00 81.10 -- -- IBM 1280x1024 75.00 80.00 pos pos SUN 1280x1024 76.10 81.10 Composite sync IBM 1280x1024 85.00 91.10 pos pos IBM 1280x1024 100.10 108.50 pos pos IBM 1360x768 60.00 47.70 pos pos IBM 1400x1050 60.00 65.30 neg pos IBM 1400x1050 75.00 82.
SERIAL NUMB ER RUMA-010950 rev 12-22-05 v3.1 Runco International • 2900 Faber Street • Union City, CA 94587 • Ph (510) 324-7777 / (800) 23RUNCO / Fax (510) 324-9300 www.runco.