- RUNCO International OWNER'S OPERATING MANUAL 1080p Digital Light ProcessingTM Projector and Digital High Definition (DHDTM) Controller VX-44d, VX-55d
Table Of Contents
- TWO YEAR LIMITED WARRANTY
- Safety Precautions
- 1. Introduction
- 2. Controls and Functions
- 3. Installation
- 3.1 Remote Control
- 3.2 Quick Setup
- 3.3 Installation Considerations
- 3.4 Installing the Projection Lens
- 3.5 Installing the Optional CineWide Lens Mount
- 3.6 Mounting the VX-44d/-55d
- 3.7 Connections to the VX-44d/-55d and DHD Controller
- Connector Panel Access
- Connecting the DHD Controller to the VX-44d/-55d
- Connecting Source Components to the DHD Controller
- RS-232 Controller Connection
- Connecting 12-Volt Trigger Outputs to External Theater Equipment
- Connecting an External IR Receiver to the DHD Controller
- Connecting to AC Power
- 3.8 Turning on the Power
- 3.9 Adjusting the Picture Orientation
- 3.10 Primary Lens Adjustments
- 3.11 Installing and Adjusting the CineWide Anamorphic Lens
- 3.12 Calibrating Projector Input 2 (DVI)
- 3.13 Working With the Lamp
- 4. Operation
- 5. Maintenance and Troubleshooting
- 6. Serial Communications
- 7. Specifications
Serial Communications
92 Runco VX-44d/-55d Owner’s Operating Manual
P
RELI
M
INARY
Input Position Commands
IHEIGHT -100/100 YES Sets the value for input height
IHEIGHT? NA NA Returns input height value
IHPOS -100/100 YES Sets a value for horizontal input position
IHPOS? NA NA Returns input horizontal position value
IVPOS -100/100 YES Sets a value for vertical input position
IVPOS? NA NA Returns input vertical position value
IWIDTH -100/100 YES Sets the value for input width
IWIDTH? NA NA Returns input horizontal width value
OVERSCAN 0/10 YES Sets the overscan percentage
OVERSCAN? NA NA Returns overscan percentage
Output Shift Commands
OHEIGHT -100/100 YES Sets the value for output height
OHEIGHT? NA NA Returns output height value
OHPOS -100/100 YES Sets the value for output horizontal position
OHPOS? NA NA Returns output horizontal position value
OVPOS -100/100 YES Sets the value for output vertical position
OVPOS? NA NA Returns output vertical position value
OWIDTH -100/100 YES Sets the value for output width
OWIDTH? NA NA Returns output horizontal width value
Table 6-1. Serial Commands (continued)
Command
Parameter
(min/max)
Value
Stored?
Description