User's Manual

Maintenance and Troubleshooting
78 Runco VX-44d/-55d Installation/Operation Manual
PRE
L
IMINAR
Y
4. Grasp the lamp by its housing only and pull it straight out (lamp slides along guides)
until it’s free; see
Figure 5-3. Discard the lamp using safe disposal/recycling practices
or contact your Runco dealer for a possible re-lamping program.
Figure 5-3. Removing the Lamp
5. Align the new lamp with the top and bottom guides on the left side of the lamp
compartment; see
Figure 5-4. Slide the lamp all the way in. A slightly harder push may
be required right at the end to make sure it is fully seated into the terminal block.
NOTE: The projector will not power up again if the lamp is not fully connected to the
terminal block.
Figure 5-4. Installing A New Lamp
6. Pull (out) and turn the lamp lock lever (turned up in Step 3) a quarter turn clockwise to
“lock” the lamp in place.
7. Replace the lamp door and secure it with the screws.
8. Re-attach the power cord to the projector and power it up.
9. Record the New Lamp Serial Number: Perform the steps listed in Lamp Hours
Reset on page 73.
If you can’t turn the lamp lock into position, the lamp may not be
fully inserted. In this case, partially remove the lamp and try pushing
it back in again. Then, try switching the lock lever to the “lock”
position.
Always record the serial number of a new lamp. Do this only if you
have just installed a new lamp. This will ensure that the lamp timer
is not reset on an old lamp and that the number of hours logged on
the lamp is accurate.
Note
Note