Installation guide

Configuration Scenarios
Runco WindowWall Installation Guide 105
Cabling
Because the Runco WindowWall has position sensing, LCDs can be cabled to the
Quad Input Manager Modules in any way that is convenient. Keep in mind that most
of the configuration menus will appear on the module connected to LCD 1 on the A
Quad Input Manager Module so you may want to put that one in a convenient
location.
The Loop Out connector of each Quad Input Manager Module should be connected
to the Dual Link In connector of the next module. The final Loop Out connector
should be connected back to the Dual Link In connector of the first module.
Note: Cabling video loop connections.
Source Routing
There is a quick configuration for Runco Big Picture. Choose the input you want to
display on the whole wall for the
QUICK CONFIGURE BIG PICTURE line in the WALL
CONFIGURATION menu. In order for this Quick Configure to work correctly, you must
have previously allowed the system to discover its display positions by choosing
AUTO in the MATRIX LAYOUT menu.