RF302E RF302PLUS Thank you for choosing our products.Please read the instructions carefully before installation and keep it available for future maintenance or reference. Our company reserves the right of final interpretation for this manual. The manual is subject to change without notice. Customer Service:info@runfinegroups.
Content Installation Maintenance Others Important Safeguards 01 Technical specification 03 List of materials 05 Technical drawings 06 Parts identification 07 Installation of ceramic toilet 08 Previous preparation 10 Auto lid open/close 11 Daily maintenance 12 Emergency troubleshooting 13 Function keys description 15 Troubleshooting Guide 16 1.Main unit care and maintenace 2.Spray nozzle maintenance and care 1.Electricity and water supply cut-off 2.Failure of remote control 3.
IMPORTANT SAFEGUARDS When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following: 1.The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. 2.Children being supervised not to play with the appliance. 3.
IMPORTANT SAFETY INSTRUCTIONS CAUTION – Indicates that failure to follow the instruction may cause body injury or property damage. 1. Do not install or use the product in wet places as steam room etc. 2. It is recommended to use water-proof electrical outlet which should be lnstalled in the place where is not easily got wet. 3. This product should be used with 110V-120V,50/60Hz electrical current only,load current is at least 15A.
Technical Specification Rating pressure 110V-120V,50/60Hz Main Unit Rating power 1200W-1400W Water pressure Minimum water pressure 0.07MPa (20L/min. flow). range Maximum water pressure 0.8MPa (Hydrostatic pressure) Electrical wire length is about 1.8m Flush volume 1.6/1.1Gpf(6.0/4.
Surface temperature Heating power Heated seat Open and close device Heated burning protection Safety device Night light assembly User ID setting Caring device Automatic flushing Auto lid open/ close(optional) 04 6 different level adjustment 50W Quiet soft-closing device,Auto open and close(Only for model RF302PLUS) The seat temperature will automatically lower to level 1 in 10 minutes after using Seat sensor, Temperature sensor, Bimetallic thermostat, Temperature fuse intelligent,often in the off stat
List of materials AUTO AUTO REAR FRONT PRESSURE MASSAGE AUTO DRY REAR POSITION PRESSURE STOP DRY ENERGY SAVER Main Unit WATER DRY POSITION STOP SEAT NOZZLE CLEANING FLUSH FRONT MASSAGE DRY ENERGY SAVER WATER SEAT NOZZLE CLEANING FLUSH RF302E RF302PLUS Remote controller components RF302E RF302PLUS Thank you for choosing our products.Please read the instructions carefully before installation and keep it available for future maintenance or reference.
Technical drawing 455 405 575 1100 390 730 The product shape chart is for reference only, and we reserve the right to modify the appearance of the product.
Parts identification Bumper Left side Lid Power indicator Energy saving indicator Human body sensing window Remote sensing window Human body sensing window Rear cleaning button Seat Drying button Power button Ceramic toilet Flush button Front cleaning button Water discharging Front cleaning Spray nozzle Nozzle baffle Drying baffle Half flush button Rear cleaning Full flush button Main unit disassembly button Deodorization window Right side Remote sensing window 07
Installation of ceramic toilet 1.Water supply angle valve installation Draw drain outlet centerline on the floor, Install angle valve at proper position on wall according to dimension of toilet. Angle valve 3.Mounting bracket installation Assemble the mounting bracket with bolts and then install them to the pre-installed flange plate on the ground and lock tight with nuts. Washer Line Mounting bracket Bolt Nut Drain outlet 4.Ceramic toilet installtion 2.
Fixing sleeve Screw Decorative cap 5.Installation of hose Connect water inlet and angle valve by new hose. Put the screw through the fixing sleeve and then install it through the holes(on both sides of the toilet ceramic) to the mounting bracket on the ground, and lock tight with a tool; Put the decorative cap on the fixing sleeve.
Previous preparateion 1. Turn on the angle valve Check thread connection,make sure no leakage is found. Angle valve 2.Switch the power supply Insert electric leakage protection plug into power socket. Indicator light Electric leakage test button Protection switch 3.
Auto lid open/close If you purchase the intelligent toilet with auto lid open/close function, the product can achieve the function of auto lid open/close. The factory default of this function is on closed situation, so please start the auto lid open/close function by using remote controler. 1. When user close to the toilet 1.
Daily maintenance Main unit care and maintenace Spray nozzle maintenance and care 1.Shut off power supply at maintenance. 1.Nozzle self-cleaning Press “nozzle cleaning” button and nozzle will move forward and self-clean. 2.Turn the seat upward open, press down the button located on the right side of main unit and pull out the seat.Wipe the stain with a soft damp cloth. 2.Spray nozzle disassemble When the wand moves forward,the nozzle can be disassembled to clean. 3.
Emergency Troubleshooting 1. Power failure Manually press button of full/half flush to perform the toilet flushing. Operation panel 2.Water failure Put around 8L water into a barrel and flush the bowl of ceramic. Note:Avoid water spilling from bowl.
Emergency Troubleshooting Failure of remote control 1.Operate the panels on ebidet seat to perform. When the product is left unused for long time Especially in winter season,the water inside the tank should be discharged to avoid freezing. To discharge water 1.Turn off the water supply angle valve 2.Cut off the electricity 3.Discharge water Slightly press inward the discharging button to discharge water. 2.Battery replacement Press the “power” button on panel and electricity indicator will turn off.
The illustration of main unit keys Power Flush Dry Front Rear 1. Long press "power" button to enter standby mode; and then quick press "power" button to restore functional mode. 2. When people sit, press "power" button to stop the function of rear, front cleaning or drying. When no one sits, press "power" button to switch between function mode and power save mode. Press "flush" button to activate full flushing. Press "dry" button, warm wind will come out.
Troubleshooting Guide Problem No flushing Cause Water supply hose buckling causes block Solve the buckling Fill valve is off Turn on the fill valve Water supply is cut off Connect water supply and wait for the water Water supply hose buckling causes partial block Fill valve is not fully Poor flushing turned on Filter is dirty and causes block The water temperature is setted The water is not hot on normal temperature level Seat temperature is not hot Wind temperature is not hot No wind out Spray wand
ASVFAD051400000A-1.