Instruction Manual

8
30 IPS, Input @ -0 dBu -3dBu @ 120kHz
Saturation @ minimum -3dBu @ 10Hz
+3.15dBu Peak @ 125Hz
Saturation @ maximum -3dBu @ 100kHz
-3dBu @ 12.5Hz
+1.3dBu Peak @ 110Hz
TOTAL HARMONIC DISTORTION AND NOISE
Refer to sweeps on page10
15 IPS, Input @ -0 dBu 0.4% @ 3kHz to 1% @
175Hz typical
Saturation @ minimum Greater than 1% below
175Hz typical
Saturation @ maximum 1% at 6kHz typical
0.3% @ 1kHz to 3% @
50Hz typical
30 IPS, Input @ -0 dBu 1% at 1kHz typical
Saturation @ minimum 0.6% @ 400Hz to 5% @
20Hz typical
Saturation @ maximum 1.5% @ 20kHz to 0.4% @
1kHz typical
0.4% @ 1kHz to 2% @
50Hz typical
POWER REQUIREMENTS:
Supplied by 500 series rack with 110-125 mA @ +/- 16V DC