URussound R290DS J POWER: AMPLIFIER
SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER. NO USERSERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
TABLE OF CONTENTS Safety Instructions 2 Product Overview 4 Front and Rear Panels 5 System Configuration - Stereo Mode 6 System Diagram - Stereo Mode 7 System Configuration - Bridged Mode 8 System Configuration - External Volume Control 9 Technical specifications 10 Warranty 11 Russound R290DS Installation Manual 3
PRODUCT OVERVIEW Introduction Protection Circuitry The Russound R290DS is a 2-channel90 watt dual source power amplifier with auto-source switching. It features Primary and Secondary audio line inputs with a loop out to another zone, receiver, or device from the Primary source. A signal only available as a speaker input can be connected and assigned as either the primary or secondary source. Special circuitry has been designed into the amplifier to safeguard under a short-circuit condition.
FRONT AND REAR PANEL ------ ------- URussound ell @ R290DS POWElf AMPllFIElI Status Indicator LED Red - Standby Green - Active Orange -Short Circuit Protection Primary Input/Output Secondary Input ------ .~ 12VDC TrigerOut IlV IOOmA @ @ @ Trluerln I1V I Stereo / Bridge Switch q~ Power Switch ~ Secondary Line I URussound ~ I CE R - ~<~,. Newmarket NH USA In ... ~'--" lIS '1c,-, Power Amplifier R290DS L@ @ R@ (. Speaker Level Input ~~~~m~ BB III ,.
SYSTEM CONFIGURATION - STEREO MODE The R290DS has dual source capability. If two sources are used, connect the source you want to have priority to the Primary input and the other source to the Secondary input. Whenever the Primary source is active, that signal will take priority over the distributed audio signal on the Secondary line.
SYSTEM DIAGRAM - STEREO MODE .---------------- CAA66 Multizone Controller --- --------------------------- Line Out RCA Cable Spuke,Ou< 8rid,..ModeOutpu. '," Ii![] I AC 110\1- ( __ ~ A(: H~V - '",_1l0V ,~ J"")O[]\I" J\.>., 'l).1\I)~, rust .... -------T IM'1~O.\ ~l'iC" l¥.f/rr1v.H1~: ----------------- =J R290DS Amplifier 8!~~j8 ~ D <-I -'1 000000 0 0 00 000 000 Line Out RCA Cable CD -'~---_.
SYSTEM CONFIGURATION - BRIDGED MODE Bridged Mode In this mode both the left and right channels are combined for a higher power mono output. For proper operation, the left channel adjustment should be set to the center position to start and then adjusted appropriately from there. The right channel adjustment is not applicable. 1. Unplug the R290DS. 2. Set the Stereo/Bridge switch to Bridge Mono. 3. Connect the line out from a preamplifier or source to the Left Primary input jack of the R290DS.
SYSTEM CONFIGURATION - EXTERNAL VOLUME CONTROL System Configuration with External Volume Control The R290DS can be configured for large autoformer-based volume control systems/speaker selectors.
TECHNICAL SPECIFICATIONS R290DS Amplifier Continuous Output Power: «0.1 % THD=N) @ 1kHz Distortion THD+N: Signal-to-Noise Ratio: Channel Separation: Frequency Response: Input Sensitivity: Input Impedance: Voltage Gain: Power Requirements: <0.3% from 20Hz to 20kHz for 90W into 8 ohms <0.5% from 20Hz to 20kHz for 1W into 8 ohms > 11 OdS A-weighted > 70dS @ 1 kHz 20Hz to 20kHz +/- O.
WARRANTY Warranty The Russound R290DS Power Amplifier is fully guaranteed against all defects in materials and workmanship for two (2) years from the date of purchase. During this period, Russound will replace any defective parts and correct any defect in workmanship without charge for either parts or labor. For this warranty to apply, the unit must be installed and used according to its written instructions. If service is necessary, it must be performed by Russound.
R290DS Dual Source Power Amplifier Installation Manual