Instruction manual

19
INSTALLER SECTION
Installation
Wire Color Polarity
White Left +
Green Left –
Black Right –
Red Right +
Doorbell connections
ComPoint can either provide a doorbell function
or operate a separate doorbell system. To use
a separate doorbell, connect each door station
to the doorbell as shown in figure 21 or the
doorbell system instructions.
Door strike release connections
The door strike release module has 110 punch-
down connectors for the hub and door station
cables. It also has screw terminals for its relay
contacts that accept up to 14 AWG stranded
wire. Figure 22 shows the connections.
Hub modular connections
The hub has 8-pole modular jacks for keypad
and door station connections. The keypads con-
nect to ports 1 through 6, and the door stations
connect to DOOR1 and DOOR2. These connec-
tions must be made according to the T568A
standard as shown in figure 23.
The hub also uses modular jacks for the link
ports. You may use any 8-pole straight-through
patch cable to link hubs together.
Fig. 20. Speaker connection to keypad
y
OUT TO SPEAKERS IN FROM AMPLIFIER
L+ L- R - R+ L+ L- R- R+
Fig. 21. Doorbell connection to door station
Doorbell
Transformer
Doorbell
Fig. 22. Door Strike Release Module connections
To door strike
release unit
To ISK3
Door Station
From ISH1 Hub
Fig. 23. 8-pole modular T568A connection
Speaker connections
(cont’d)