Instruction manual

22
INSTALLER SECTION
Programming
To assign labels you must have all hubs linked
together with unique ID numbers (if the system
has multiple hubs) and an ISK2 Advanced
Keypad connected to any hub. You can use the
same keypad to assign labels for the entire sys-
tem. Also, the system must be powered up.
Assigning zone labels
To assign zone labels, follow these steps (or the
Zone Name Procedure flow chart on page 24):
1. Remove the wall plate if
it’s installed. Press and
release the Setup button
on the right edge of the
keypad (figure 25) to
enter the main menu.
The display shows
ZName (ZONE NAME).
2. Press the Talk key to
enter the Zone Name
procedure. The display
shows Zn#? to prompt
you to select a zone
number.
3. Press the Talk key again
for the next sequential
zone to be assigned or
use the Volume Up or
Volume Down key to select a specific zone. You
can press and hold the key to scroll through the
list of zones with a half-second delay between
items. Stop at the desired zone number.
4. Press and release the Talk key. The display shows
Name? to prompt you to assign a zone label.
5. Use the Volume Up or Volume Down key to select
a label from the list of zone labels. You can press
and hold the key to scroll through the list of zone
labels with a half-second delay between items.
Stop at the desired label.
6. Press and release the Talk key to save the selec-
tion. The display shows Zn#? to prompt you to
select the next zone.
7. Repeat steps 3 through 6 for the remaining zones.
Press and release the Setup button to exit the
procedure. You can then go to the Door Name
Procedure by pressing the Next key or press
the Setup button again to exit the main menu.
Note:
If you aren’t sure which zone an ISK2
keypad is connected to, you can find out by
observing the keypad’s display when powering
up the system. When a hub is powered up, each
keypad connected to that hub briefly indicates
Page, then indicates the port and hub number
to which it is connected. For example, an indica-
tion of P4:H2 shows the keypad is connected to
port 4 on hub 2. This indication remains for 3
seconds, then reverts to Page.
Zones are numbered sequentially starting with
hub 1, port 1. Table 5 shows zone numbers and
port assignments.
Table 4. Assignable door labels for ISK2
Table 5. Zone port assignments
Door Label Door Name
BDoor Back Door
FDoor Front Door
Gate Gate
Grage Garage
SDoor Side Door
SvcDr Service Door
Fig. 25. ISK2 Setup Button
Zone Port Zone Port Zone Port
1 P1:H1 13 P1:H3 25 P1:H5
2 P2:H1 14 P2:H3 26 P2:H5
3 P3:H1 15 P3:H3 27 P3:H5
4 P4:H1 16 P4:H3 28 P4:H5
5 P5:H1 17 P5:H3 29 P5:H5
6 P6:H1 18 P6:H3 30 P6:H5
7 P1:H2 19 P1:H4 31 P1:H6
8 P2:H2 20 P2:H4 32 P2:H6
9 P3:H2 21 P3:H4 33 P3:H6
10 P4:H2 22 P4:H4 34 P4:H6
11 P5:H2 23 P5:H4 35 P5:H6
12 P6:H2 24 P6:H4 36 P6:H6
Zone and door station labels
(cont’d)