Installation manual

21
Russound MCA-C5 User and Installation Manual
Rev. 1
Linked Controllers
MULTIPLE CONTROLLER INSTALLATION
Linking Multiple Controllers
The RNET Link In and Link Out can be used to connect two or more (up to 6)
MCA-C5 controllers (does not support CAV6.6, CAM6.6 or CAA66 controllers).
The connection is made using a CAT-5e patch cable from the Link Out of the
rst controller and into the Link In of the next controller. Along with RNET data
signals, the RNET Link In and Link Out port passes source IR signals.
The CAT-5e patch cable must have an RJ-45 connector on each end with
T568A wiring conguration. It can not exceed 18 inches (45.7 cm) in length
to avoid potential cross-talk between the source-specic IR repeating signal
lines.
Controller ID Switch Settings
The Controller ID switch is a rotary switch with seven positions. It is used to set
the controller ID number for multi-controller systems, and to put the MCA-C5
into Firmware Update mode.
If two or more MCA-C5 controllers are connected using the RNET Link In and
Link Out ports, each controller must have a unique controller ID prior to being
connected through the RNET ports. Set each controller’s ID switch to a unique
number. Any multi-controller conguration requires that one controller be set
to controller ID #1. This action must be performed before the system setup
procedure is completed through SCS-C5 software and before powering up the
system. The small arrow on the dial should point at the desired setting.
MCA-C5 Controller (ID#2)
MCA-C5 Controller (ID#1)
CAT-5e Cable
Rotate switch to point arrow
to the intended position