CA6.4 Central Controller/Amplifier Manual

7. Back Panel Connections
7.1 Source Input Connections
Your source inputs are located at the top left corner of the back panel. Connect each source output, left and
right, using quality signal cables / patch cables. Label each cable the name of your source and the input num-
ber of the CA6.4 you have selected. Repeat until all sources are connected. List them down below.
figure 1 Input 1 ______________ Input 2 ______________ Input 3 ______________ Input 4 ______________
7.2 Speaker Connections
Keeping in mind the location of the corresponding keypad, connect your speakers by first removing the connec-
tor. Using wire strippers, strip back 1/8" of the end of the wire. Insert the proper polarity, left + to left +, left- to left-
etc., until all wires are connected in each zone output. Label each wire with the room name and zone number.
Write down the room name to the zone number below. Note: Connect 8 Ohm minimum speakers only.
figure 2 (Color) Left + _____________ Left - _____________ Right + _____________ Right - _____________
Zone 1 ________________________ Zone 2 ________________________ Zone 3 ________________________
Zone 4 ________________________ Zone 5 ________________________ Zone 6 ________________________
7.3 Connecting The Infra-red Components (diagram on next page)
In order for your CA 6.4 to transmit the IR signal from the keypads to a source, an emitter must be connected
from the IR outputs marked 1-4. Each of these outputs are wired in series and must be connected in consecu-
tive order. For example, the #1 emitter output must be connected in order for the #2 emitter output to transmit
the IR command.
Connect each 845 mini-emitter to the source IR output. Refer to the source number you had written down
above figure 1.
MADE IN KOREA
INPUT FROM KEYPADS
43 21
OUTPUT TO 8 SPEAKERS
43 21
2345678 12345678 12345678 12345678
WARNING : SHOCK HAZARD
DO NOT OPEN
AVIS : RISQUE DE CHOC
ELECTRIQUE NES PAS OUVRIR.
SERIAL #
~110VAC
~220-240VAC
~50-60Hz
400W
~110VAC~220-240VAC
VOLTAGE
110V
220-240V
FUSE
F4A
F2A
AC110/240
Input
Fuse
Holder
Voltage Selector
Switch
5