Use and Care Manual

TECHNICAL DATA
PROFESSIONAL DTM ALKYD ENAMEL GALLONS
Rust-Oleum Corporation Form: CS2309
11 Hawthorn Parkway Phone: 877•3858155 Rev.: 032913
Vernon Hills, Illinois 60061 www.rustoleum.com
An RPM Company
PHYSICAL PROPERTIES .
450 VOC FINISHES
400 VOC FINISHES
100 VOC FINISHES
Resin Type
Modified Alkyd
Modified Alkyd
Oil Modified Alkyd
Pigment Type
Varies with color
Varies with color
Varies with color
Solvents
Aliphatic hydrocarbons
Aliphatic hydrocarbons
Exempt halogenated and
hydrocarbon solvents
Weight
Per Gallon
7.6-8.9 lbs.
7.6-8.9 lbs.
9.0-10.4 lbs.
Per Liter
0.9-1.1 kg
0.9-1.1 kg
1.1-1.2 kg
Solids
By Weight
51-59%
56.1-62.8%
46.0-54.8%
By Volume
42-43%
48.3-48.5%
46.6-48.0%
Volatile Organic Compounds
<450 g/l (3.75 lbs./gal.)
<400 g/l (3.33 lbs./gal.)
<100 g/l (0.83 lbs./gal.)
Recommended Dry Film
Thickness (DFT) Per Coat
1.5-2.5 mils
(37.5-62.5µ)
1.5-2.5 mils
(37.5-62.5µ)
1.5-2.5 mils
(37.5-62.5µ)
Wet Film to Achieve DFT
(unthinned material)
3.5-6.0 mils
(87.5-150µ)
3.0-5.0 mils
(75-125µ)
3.5-5.5 mils
(87.5-137.5µ)
Theoretical Coverage at 1 mil
DFT (25µ)
675-690 sq.ft./gal.
(16.6-17.0 m
2
/l)
775-780 sq.ft./gal.
(19.1-19.2 m
2
/l)
750-770 sq.ft./gal.
(18.5-18.9 m
2
/l)
Practical Coverage at
Recommended DFT
(assumes 15% material loss)
230-390 sq.ft./gal.
(5.7-9.6 m
2
/l)
265-440 sq.ft./gal.
(6.5-10.8 m
2
/l)
255-435 sq.ft./gal.
(6.3-10.7 m
2
/l)
Tack-free
2-4 hours
2-4 hours
4-6 hours
Handle
5-9 hours
8-12 hours
8-12 hours
Recoat
24 hours (allow more time at cooler temperatures)
Dry Heat Resistance
212°F (100°C)
200°F (93°C)
212°F (100°C)
Shelf Life
5 years
5 years
5 years
Flash Point
104°F (40°C)
Safety Information
For additional information, see MSDS.
The technical data and suggestions for use contained herein are correct to the best of our knowledge, and offered in good faith. The statements of this literature
do not constitute a warranty, express, or implied, as to the performance of these products. As conditions and use of our materials are beyond our control, we
can guarantee these products only to conform to our standards of quality, and our liability, if any, will be limited to replacement of defective materials. All
technical information is subject to change without notice.