MSDS

Page 4/11
Safety Data Sheet
according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and
GHS
Printing date 29.09.2014 Revision: 29.09.2014
Trade name: RockSolid Fast Patch Part B
(Contd. of page 3)
39.4.1
Contains 2,4,6-tris(dimethylaminomethyl)phenol. May produce an allergic reaction.
SECTION 5: Firefighting measures
·
5.1 Extinguishing media
·
Suitable extinguishing agents:
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
·
For safety reasons unsuitable extinguishing agents:
None.
·
5.2 Special hazards arising from the substance or mixture
Formation of toxic gases is possible during heating or in case of fire.
·
5.3 Advice for firefighters
·
Protective equipment:
Wear self-contained respiratory protective device.
Wear fully protective suit.
·
Additional information
Use large quantities of foam as it is partially destroyed by the product.
SECTION 6: Accidental release measures
·
6.1 Personal precautions, protective equipment and emergency procedures
Ensure adequate ventilation
Wear protective equipment. Keep unprotected persons away.
For large spills, use respiratory protective device against the effects of fumes/dust/aerosol.
·
6.2 Environmental precautions:
Do not allow to enter sewers/ surface or ground water.
·
6.3 Methods and material for containment and cleaning up:
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Pick up mechanically.
Dispose contaminated material as waste according to item 13.
·
6.4 Reference to other sections
See Section 7 for information on safe handling.
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
SECTION 7: Handling and storage
·
7.1 Precautions for safe handling
Use only in well ventilated areas.
Prevent formation of aerosols.
Avoid splashes or spray in enclosed areas.
·
Information about fire - and explosion protection:
No special measures required.
·
7.2 Conditions for safe storage, including any incompatibilities
·
Storage:
·
Requirements to be met by storerooms and receptacles:
Avoid storage near extreme heat, ignition sources or open flame.
Protect from humidity and water.
(Contd. on page 5)