SDS

Date Printed: 11/16/2018
5. Fire-Fighting Measures
EXTINGUISHING MEDIA: Alcohol Film Forming Foam, Carbon Dioxide, Dry Chemical, Dry Sand, Water Fog
UNUSUAL FIRE AND EXPLOSION HAZARDS: FLASH POINT IS LESS THAN 20°F. EXTREMELY FLAMMABLE LIQUID AND
VAPOR!Water spray may be ineffective. Closed containers may explode when exposed to extreme heat due to buildup of steam.
Closed containers may explode when exposed to extreme heat. Vapors may form explosive mixtures with air. Vapors can travel to
a source of ignition and flash back. Keep containers tightly closed. Isolate from heat, electrical equipment, sparks and open flame.
Perforation of the pressurized container may cause bursting of the can. No unusual fire or explosion hazards noted.
SPECIAL FIREFIGHTING PROCEDURES: Water may be used to cool closed containers to prevent pressure buildup and possible
autoignition or explosion. Full protective equipment including self-contained breathing apparatus should be used. Evacuate area
and fight fire from a safe distance. Use water spray to keep fire-exposed containers cool. Containers may explode when heated.
Special Fire and Explosion Hazard (Combustible Dust): No Information
6. Accidental Release Measures
STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED: Contain spilled liquid with sand or earth. DO NOT use
combustible materials such as sawdust. Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Remove all sources of ignition, ventilate area and remove with inert absorbent and non-sparking tools. Dispose of according to
local, state (provincial) and federal regulations. Do not incinerate closed containers. Ventilate area, isolate spilled material, and
remove with inert absorbent. Dispose of contaminated absorbent, container, and unused contents in accordance with local, state,
and federal regulations.
7. Handling and Storage
HANDLING: Wash thoroughly after handling. Wash hands before eating. Remove contaminated clothing and launder before reuse.
Use only with adequate ventilation. Follow all SDS and label precautions even after container is emptied because it may retain
product residues. Avoid breathing fumes, vapors, or mist. Avoid contact with eyes, skin and clothing.
STORAGE: Store in a dry, well ventilated place. Keep container tightly closed when not in use. Keep containers tightly closed.
Isolate from heat, electrical equipment, sparks and open flame. Contents under pressure. Do not store above 120 ° F. Store large
quantities in buildings designed and protected for storage of flammable aerosols. Keep away from heat, sparks, flame and sources
of ignition. Avoid excess heat. Product should be stored in tightly sealed containers and protected from heat, moisture, and foreign
materials.
Advice on Safe Handling of Combustible Dust: No Information
8. Exposure Controls / Personal Protection
Chemical Name CAS-No.
Weight %
Less Than
ACGIH TLV-
TWA
ACGIH TLV-
STEL
OSHA PEL-TWA
OSHA PEL-
CEILING
Naphtha, Petroleum,
Hydrotreated Light
64742-49-0 25.0 N.E. N.E. N.E. N.E.
Propane 74-98-6 20.0 N.E. N.E. 1000 ppm N.E.
n-Butane 106-97-8 10.0 N.E. 1000 ppm N.E. N.E.
Xylenes (o-, m-, p- isomers) 1330-20-7 10.0 100 ppm 150 ppm 100 ppm N.E.
Acetone 67-64-1 10.0 250 ppm 500 ppm 1000 ppm N.E.
Hydrous Magnesium Silicate 14807-96-6 5.0 2 mg/m3 N.E. N.E. N.E.
Hydrotreated Light Distillate 64742-47-8 5.0 N.E. N.E. N.E. N.E.
Ethylbenzene 100-41-4 5.0 20 ppm N.E. 100 ppm N.E.
Octane 111-65-9 5.0 300 ppm N.E. 500 ppm N.E.
n-Heptane 142-82-5 5.0 400 ppm 500 ppm 500 ppm N.E.
Stoddard Solvent 8052-41-3 1.0 100 ppm N.E. 500 ppm N.E.
Methyl ethyl ketoxime 96-29-7 1.0 10 ppm N.E. N.E. N.E.
PERSONAL PROTECTION
ENGINEERING CONTROLS: Use process enclosures, local exhaust ventilation, or other engineering controls to control airborne
levels below recommended exposure limits. Use explosion-proof ventilation equipment. Provide general dilution of local exhaust
ventilation in volume and pattern to keep TLV of hazardous ingredients below acceptable limits. Prevent build-up of vapors by
opening all doors and windows to achieve cross-ventilation.
RESPIRATORY PROTECTION: A respiratory protection program that meets OSHA 1910.134 and ANSI Z88.2 requirements must
be followed whenever workplace conditions warrant a respirator's use. A NIOSH/MSHA approved air purifying respirator with
organic vapor cartridge or canister may be permissible under certain circumstances where airborne concentrations are expected to
exceed exposure limits.
Page 3 / 6