Data Sheet
Specifications
9310
In or Out...we make it Easy!
®
Easy Read-Magstripe
TM
Card Reader Operation
©2011 RUTHERFORD CONTROLS INT’L CORP. WWW.RUTHERFORDCONTROLS.COM
USA: 2517 SQUADRON COURT, SUITE 104, VIRGINIA BEACH, VA 23453 • CANADA: 210 SHEARSON CRESCENT, CAMBRIDGE, ON N1T 1J6
PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-MAIL: SALES@RUTHERFORDCONTROLS.COM
Operating Temperature
Cable
Voltage Input
Construction
Power/Current
Capability
Request-to-Exit
Input Capability
Housing Dimensions
Chrome 1-3/8” W x 3-1/2”H x 1-3/8” D
Yes
Max 500mA @ 12VDC (Continuous)
Stainless steel read head
Mazak “Satin Chrome” metal
12VAC or 12VDC*
10 ft (supplied)
black, white and gray twin flex
-5 to 160ºF -20 to 70ºC
Swipes
In excess of 1,000,000
Enrolling a User
• Write the user’s name on the shadow card.
• Swipe the paper shadow card through the reader
followed by the magstripe card you wish to enroll.
• File the shadow card in a safe place, the user is now
programmed to use the personal magstripe card as a pass.
Deleting a User
• Swipe the shadow card bearing the name of the unwanted user.
• The shadow card can then be used again to enroll another user
on the reader, if desired.
“Door Open”
Time Frame
0.5 to 5,000 seconds
NOTE: Specifications are subject to change without notice.
*Reader includes lock mode card, master card, 100 shadow cards, plug-in
transformer. If used with an electromagnetic lock, RCI recommends our 10-Series
12VDC power supplies. All installations must conform to local fire codes, national
building codes and life safety codes.
Track Read
ANSI Track II standard
(special order others)
Voltage Output
12VDC
Specifications
Use with Electric Strikes or Electromagnetic Locks*
• Swipe the lock mode card to convert to fail unlocked
(fail safe) operation for electromagnetic locks.
• Swipe the lock mode card at any time to change back to
fail locked (fail secure) operation for electric strikes.
*NOTE: Installation must comply with local codes.
Initializing the Unit
The reader operates with a starter card pack which contains
a master card and 100 enrollment (shadow) cards. When
the reader is powered up for the first time it will need to be
initialized by swiping the master card through it. The reader
will then accept the remaining cards.
Setting “Door Open” Time
• Swipe the master card through the reader.
• Wait for the amount of time you wish the door to remain
unlocked after swiping.
• Swipe the master card again.
• The door open time is now set as the interval between
the first and second swipes of the master card.
Swiping this card through the reader
will bar or enroll a card.
LOCK MODE
MASTER CARD
ENROLLMENT (Shadow) CARD
Write name
1. Enrollment of shadow card pack: Initial swipe of this
card enables shadow packs for use.
2. Door unlock time: Swipe this card, the reader will
"beep" once per second. Wait for the desired "door
unlock" time, then swipe again. (3-5 seconds is
usually sufficient.)
Swipe this card to convert lock mode from Fail
Locked/Fail Secure (power supplied), to Fail
Unlocked/Fail Safe (power interrupted).
EASY READ