Owner's Manual
INSTALLATION
9310
Easy Read-Magstripe
®
Card Reader
NOTE: READER IS WEATHER-RESISTANT. Do not apply sealant or gaskets to the rear of the reader, as this may cause condensation
to build up and adversely affect reader operation.
Electrical Installation Instructions
©2013 RutheRfoRd contRols • www.RutheRfoRdcontRols.com
usA: 2517 sQuAdRon couRt, suIte 104, VIRGInIA BeAch, VA 23453 • cAnAdA: 210 sheARson cRescent, cAmBRIdGe, on n1t 1j6
Phone • 1.800.265.6630 • 519.621.7651 • fAX: 1.800.482.9795 • 519.621.7939 • e-mAIl: sAles@RutheRfoRdcontRols.com
Is9310 Pcn13049
R07/13cA-1
*Drawings for reference only. All installations must conform to local fire codes, National Building codes and Life Safety Codes. Using correct wire gauge is essential. If
used with a electromagnetic lock, RCI recommends our 10 Series 12VDC power supplies. If electromagnetic lock is rated for 500+ mA, an external relay must be used.
Basic Access Control with a Door Strike
Basic Access Control with an Electromagnetic Lock
J4
+24
+12
GND
NO
NC
COM
To 12VDC
Regulated
Power Supply
Blue
Mauve
Yellow +12V
Red +
Black -
Green
GND
RCI 1000-User
Card Reader
Electromagnetic Lock*
Request
to Exit
Button
(N/O)
Red +
Yellow +
Green -
Blue
Mauve
Black -
12VDC
Electric
Strike
Request to
Exit Button
(N/O)
RCI 1000 User
Card Reader
12VDC -
1.5 Amp
Plug-In UL
Transformer
®
Mounting Instructions
1. Drill 3/8” diameter hole for wire entry.
2. Positioning the card reader over this opening, mark the
location of the two mounting screws. Drill appropriately for
mounting surface.
3. Make electrical connections as per schematic below.
4. Mount reader.
5. Engage cover at the top and pivot down. Secure with