Operating instructions
Page 17 
    Victrix Zeus 20/27 Instructions 
DL1 - Green LED that comes on when the boiler is operating in heating or antifreeze mode. 
DL2 - Green LED that comes on when the boiler is working in domestic hot water mode. 
DL3 - Orange LED that comes on when the burner is operating. 
LCD Display unit 
Depending on conditions, the LCD display indicates: 
- The boiler supply temperature. 
- The value set during heating and DHW temperature adjustment (for a time of 5 seconds after setting the 
temperature using the selector switch) 
- the wording EC (external controls) with the optional CAR remote control is used. 
- Fault conditions, the code number corresponding to the fault is displayed: 
01 = Lockout due to ignition failure 
02 = Lockout due to overheat thermostat triggering 
05 = breakage of heating NTC sensor (NR) 
10 = no-water safety device 
12 = NTC DHW sensor failure (storage tank) 
14 = incorrect ignition unit and board connection / faulty ignition unit 
16 = fan failure (faulty fan) 
17 = incorrect fan speed 
26 = no-water safety switch closed with pump not working 
31 = incompatible remote control 
Reset Button 
The Reset button is used to reset certain faults. A reset will occur when the button is pressed. 
Operation and Maintenance Instructions 
Boiler display and indicators 