User Manual

12 13
OPERATION
FULL-ROOM COVERAGE: The unit will project a line out each
end of the laser head at an approximate angle of 130˚ each
way for a total of 260˚. To cover the remainder of the work
area with a level line, turn the laser head as far as 180˚.
SELF-LEVELING MODE: If horizontal lines are desired, use
the self-leveling mode to allow the unit to automatically level.
The LED indicator located next to the thumbwheel will light
if the unit is out of level. Reposition the laser head to within
± of the horizontal plane to allow the self-leveling feature
of the level to properly function.
ANGLE-FINDER MODE: The dial indicator on top of the
laser head is an angle finder. It allows any degree angle to
be projected by the unit. To use the angle-finder:
��n Turn the laser head dial to the left to lock out the self-
leveling feature.
��n Move the laser head downward, away from the wall.
��n Wait until the arrow on the dial is pointing downward at
0˚.
��n Move the laser head to the desired angle. The scale is
graduated in 5˚ increments.
NOTE: Unit will not self-level when face of angle indicator
dial is parallel to direction of gravity.
Fig. 11
DIAL INDICATOR
ANGLE FINDER
ROTATE DIAL
LEFT FOR
ANGLE-FINDER
MODE
DOWN ARROW
INDICATES 0°
ROTATE LASER HEAD
FOR FULL-ROOM
COVERAGE
ROTATE DIAL
RIGHT FOR
SELF-LEVELING
MODE
OUT OF LEVEL
LED INDICATOR
GRAVITY