Use and Care Manual

28 - English
INSTALLING THE INDOOR KEY PAD
See Figures 45 - 49.
Locate the following items:
Indoor Key Pad
Low Voltage Wire
Insulated Staples
Entrapment Label
Screws
WARNING:
Do not use garage door opener if keypads or remotes
do not start and stop the motor. An opener that cannot
be controlled with a keypad or remote is dangerous,
can result in death or serious personal injury, and must
be repaired.
INSTALLATION
Fig. 45
WARNING:
Make sure the key pad is mounted high enough to prevent
unauthorized activation of the garage door opener. It
should be placed at least 5 feet above the floor so that
it is inaccessible to children. Unauthorized activation of
the opener can result in death or serious personal injury.
WARNING:
Do not start or stop the garage door opener if there is a
person or object in the path of the door, the door has not
been properly balanced, or if you cannot see the doorway.
Failure to follow these instructions can result in death or
serious personal injury.
WARNING:
To avoid the risk of death, electric shock, or serious
personal injury ensure that the garage door opener is
unpluged and the battery pack is removed before wiring
the key pad.
WARNING:
Connect the keypad using low voltage wires only to
prevent the risk of electric shock or serious personal
injury.
Find desired location indoors and in sight of the garage
door.
NOTE: The key pad should be at least 5 feet above the
floor so it is inaccessible to children.
Measure or estimate the distance between the desired
location and the keypad wire terminal on the garage door
operator.
Fig. 44
Twist the plain wires from both sensors together and insert
them into the remaining terminal.
For alignment instructions, see Aligning The Safety
Sensors in the Operations section.
Wire Terminal
(Door Sensor)
Wire Terminal
(Keypad)
Wires
(Striped)
Wires
(Plain)
Wires