Use and Care Manual

38 - English
OPERATION
TESTING THE AUTOMATIC REVERSAL
SYSTEM
See Figure 66.
DANGER:
Test the automatic reversal system every month and
after any adjustments are made to the garage door travel
limits. If the door contacts an object higher than 1-1/2 in.
off the garage floor (approx. the size of a 2x4 laid flat), it
should stop and reverse to the fully open position. If the
automatic reversal system does not function properly,
a
closing garage door could kill or seriously injure someone
in its path.
WARNING:
DO NOT operate the garage door opener unless the
automatic reversal system is working correctly. Following
this rule will reduce the risk of death or serious personal
injury.
Press and release the UP button to raise the garage door.
Place a 1-1/2 in. board (
approx. the size of a 2x4 laid flat)
on the garage floor beneath the door
.
Press and release the DOWN button to lower the garage
door.
When the door strikes the board, it should reverse
direction immediately.
If the garage door reverses direction after contacting the
board, the reversal system is working properly and no
adjustments are needed.
If the garage door stops before striking the board or
strikes the board and then stops, increase the travel limit
for the closed position and repeat the test.
If the automatic reversal system continues to fail, contact
customer service or a qualified service technician for
assistance.
Fig. 66
Down
Up
2 x 4